Archive

IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers with Rated Maximum Voltage above 1000 V

IEEE Std C37.011-2019 (Revision of IEEE Std C37.011-2011)

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2019

Abstract: The procedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated above 1000 V are covered in this guide. The breaking capability limits of these circuit breakers are determined to a great degree by the TRV. The TRV ratings are compared with typical system TRV duties. Examples of TRV calculation are given with suggested options if the TRV duty exceeds the TRV ratings of the circuit breaker.
URI: http://yse.yabesh.ir/std;quessioutho4703177793325273135A68A10958014A/handle/yse/276481
Subject: high-voltage circuit breakers
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (11.17Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers with Rated Maximum Voltage above 1000 V

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2020-06-18T16:56:22Z
date available2020-06-18T16:56:22Z
date issued2019
identifier isbn978-1-5044-5824
identifier other08726087.pdf
identifier urihttp://yse.yabesh.ir/std;quessioutho4703177793325273135A68A10958014A/handle/yse/276481
description abstractThe procedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated above 1000 V are covered in this guide. The breaking capability limits of these circuit breakers are determined to a great degree by the TRV. The TRV ratings are compared with typical system TRV duties. Examples of TRV calculation are given with suggested options if the TRV duty exceeds the TRV ratings of the circuit breaker.
languageEnglish
titleIEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers with Rated Maximum Voltage above 1000 Ven
titleIEEE Std C37.011-2019 (Revision of IEEE Std C37.011-2011)num
typeStandard
page127
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2019
contenttypeFulltext
subject keywordshigh-voltage circuit breakers
subject keywordsIEEE C37.011
subject keywordstransient recovery voltage (TRV)