• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • AASHTO - American Association of State Highway and Transportation Officials
  • View Item
  •   YSE
  • Industrial Standards
  • AASHTO - American Association of State Highway and Transportation Officials
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers with Less Than 2 ft of Cover Subjected to Highway Loadings

AASHTO M 273

Organization:
AASHTO - American Association of State Highway and Transportation Officials
Year: 2020

Abstract: This specification covers single-cell, precast reinforced concrete box sections with less than 2 ft of cover subjected to highway loadings and intended to be used for the construction of culverts and for the conveyance of storm water, industrial wastes, and sewage. A complete metric companion to M 273 has been developed—M 273M; therefore, no metric equivalents are presented in this specification. Note 1—This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends on the proper selection of the box section, bedding, backfill, controlled manufacture in the plant, and care that the installation conforms to the construction specifications. The owner of the precast reinforced concrete box sections specified herein is cautioned that the loading conditions and the field requirements must be correlated with the box sections specified and that inspection at the construction site must be provided. Note 2—AASHTO M 259 is to be used for box sections subjected to highway loading with 2 ft or more earth cover, or subjected to dead load only. Note 3—If load-and-resistance factor design (LRFD) is required, then use ASTM C1577
URI: http://yse.yabesh.ir/std;jsessionid=FA0D6F67C1510477F68A611DB32C1F14/handle/yse/281331
Collections :
  • AASHTO - American Association of State Highway and Transportation Officials
  • Download PDF : (1.135Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers with Less Than 2 ft of Cover Subjected to Highway Loadings

Show full item record

contributor authorAASHTO - American Association of State Highway and Transportation Officials
date accessioned2020-09-04T09:07:55Z
date available2020-09-04T09:07:55Z
date copyright2020
date issued2020
identifier otherYXAYMGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=FA0D6F67C1510477F68A611DB32C1F14/handle/yse/281331
description abstractThis specification covers single-cell, precast reinforced concrete box sections with less than 2 ft of cover subjected to highway loadings and intended to be used for the construction of culverts and for the conveyance of storm water, industrial wastes, and sewage. A complete metric companion to M 273 has been developed—M 273M; therefore, no metric equivalents are presented in this specification. Note 1—This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends on the proper selection of the box section, bedding, backfill, controlled manufacture in the plant, and care that the installation conforms to the construction specifications. The owner of the precast reinforced concrete box sections specified herein is cautioned that the loading conditions and the field requirements must be correlated with the box sections specified and that inspection at the construction site must be provided. Note 2—AASHTO M 259 is to be used for box sections subjected to highway loading with 2 ft or more earth cover, or subjected to dead load only. Note 3—If load-and-resistance factor design (LRFD) is required, then use ASTM C1577
languageEnglish
titleStandard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers with Less Than 2 ft of Cover Subjected to Highway Loadingsen
titleAASHTO M 273num
typestandard
page15
statusActive
treeAASHTO - American Association of State Highway and Transportation Officials:;2020
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian