IEC 62271-110

|French -- Appareillage à haute tension – Partie 110: Manoeuvre de charges inductives - Edition 4.0High-voltage switchgear and controlgear – Part 110: Inductive load switching - Edition 4.0

Organization:
IEC - International Electrotechnical Commission
Year: 2017

Abstract: This part of IEC 62271 is applicable to AC switching devices designed for indoor or outdoor installation, for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V and applied for inductive current switching. It is applicable to switching devices (including circuit-breakers in accordance with IEC 62271-100) that are used to switch high-voltage motor currents and shunt reactor currents and also to high-voltage contactors used to switch high-voltage motor currents as covered by IEC 62271-106. Switching unloaded transformers, i.e. breaking transformer magnetizing current, is not considered in this document. The reasons for this are as follows: a) Owing to the non-linearity of the transformer core, it is not possible to correctly model the switching of transformer magnetizing current using linear components in a test laboratory. Tests conducted using an available transformer, such as a test transformer, will only be valid for the transformer tested and cannot be representative for other transformers. b) As detailed in IEC TR 62271-306, the characteristics of this duty are usually less severe than any other inductive current switching duty. Such a duty may produce severe overvoltages within the transformer winding(s) depending on the re-ignition behaviour of the switching device and transformer winding resonance frequencies. NOTE 1 The switching of tertiary reactors from the high-voltage side of the transformer is not covered by this document. NOTE 2 The switching of shunt reactors earthed through neutral reactors is not covered by this document. However, the application of test results according to this document, on the switching of neutral reactor earthed reactors (4-leg reactor scheme), is discussed in IEC TR 62271-306.
URI: http://yse.yabesh.ir/std;quessionid=31064A12890E9/handle/yse/264728
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (1.417Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEC 62271-110

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2018-07-31T09:58:39Z
date available2018-07-31T09:58:39Z
date copyright2017.10.01
date issued2017
identifier otherSWUICGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;quessionid=31064A12890E9/handle/yse/264728
description abstractThis part of IEC 62271 is applicable to AC switching devices designed for indoor or outdoor installation, for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V and applied for inductive current switching. It is applicable to switching devices (including circuit-breakers in accordance with IEC 62271-100) that are used to switch high-voltage motor currents and shunt reactor currents and also to high-voltage contactors used to switch high-voltage motor currents as covered by IEC 62271-106. Switching unloaded transformers, i.e. breaking transformer magnetizing current, is not considered in this document. The reasons for this are as follows: a) Owing to the non-linearity of the transformer core, it is not possible to correctly model the switching of transformer magnetizing current using linear components in a test laboratory. Tests conducted using an available transformer, such as a test transformer, will only be valid for the transformer tested and cannot be representative for other transformers. b) As detailed in IEC TR 62271-306, the characteristics of this duty are usually less severe than any other inductive current switching duty. Such a duty may produce severe overvoltages within the transformer winding(s) depending on the re-ignition behaviour of the switching device and transformer winding resonance frequencies. NOTE 1 The switching of tertiary reactors from the high-voltage side of the transformer is not covered by this document. NOTE 2 The switching of shunt reactors earthed through neutral reactors is not covered by this document. However, the application of test results according to this document, on the switching of neutral reactor earthed reactors (4-leg reactor scheme), is discussed in IEC TR 62271-306.
languageEnglish
languageFrench
titleIEC 62271-110num
title|French -- Appareillage à haute tension – Partie 110: Manoeuvre de charges inductives - Edition 4.0High-voltage switchgear and controlgear – Part 110: Inductive load switching - Edition 4.0en
typestandard
page64
statusActive
treeIEC - International Electrotechnical Commission:;2017
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian