Show simple item record

Materials for printed boards and other interconnecting structures – Part 2-47: Reinforced base materials clad and unclad – Non-halogenated epoxide non-woven/woven E-glass reinforced laminate sheets of thermal conductivity 2,0 W/(m•K) and defined flammabil

contributor authorIEC - International Electrotechnical Commission
date accessioned2018-07-31T09:58:39Z
date available2018-07-31T09:58:39Z
date copyright2018.01.01
date issued2018
identifier otherSXBYCGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;quessionid=31064A12890E9/handle/yse/264729
description abstractThis part of IEC 61249 gives requirements for properties of non-halogenated epoxide non-woven reinforced core/woven E-glass reinforced surface laminate sheets of thermal conductivity and defined flammability (vertical burning test), copper-clad for lead-free assembly in thicknesses of 0,60 mm up to 1,70 mm. The flammability rating is achieved through the use of non-halogenated fire retardants reacted as part of the epoxide polymeric structure. The glass transition temperature is defined to be 105 °C minimum. Thermal conductivity is defined to be (2,0 ± 0,30) W/(m•K).
languageEnglish
titleIEC 61249-2-47num
titleMaterials for printed boards and other interconnecting structures – Part 2-47: Reinforced base materials clad and unclad – Non-halogenated epoxide non-woven/woven E-glass reinforced laminate sheets of thermal conductivity 2,0 W/(m•K) and defined flammabilen
typestandard
page26
statusActive
treeIEC - International Electrotechnical Commission:;2018
contenttypefulltext