Archive

IEC 61238-1-3

Compression and mechanical connectors for power cables – Part 1-3: Test methods and requirements for compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) tested on non-insulated conduc

Organization:
IEC - International Electrotechnical Commission
Year: 2018

Abstract: This part of IEC 61238 applies to compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV), for example buried cables or cables installed in buildings, having conductors complying with IEC 60228 having nominal cross-sectional areas between 2,5 mm2 and 1 200 mm2 for copper and between 16 mm2 and 1 200 mm2 for aluminium, excluding Milliken conductors; a maximum continuous conductor temperature not exceeding 90 °C. This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact. The object of this document is to define the type test methods and requirements which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused conductors.        
URI: http://yse.yabesh.ir/std;quessionid=31064A12890E9/handle/yse/264836
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (1.509Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEC 61238-1-3

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2018-07-31T09:58:48Z
date available2018-07-31T09:58:48Z
date copyright2018.05.01
date issued2018
identifier otherACHDFGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;quessionid=31064A12890E9/handle/yse/264836
description abstractThis part of IEC 61238 applies to compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV), for example buried cables or cables installed in buildings, having conductors complying with IEC 60228 having nominal cross-sectional areas between 2,5 mm2 and 1 200 mm2 for copper and between 16 mm2 and 1 200 mm2 for aluminium, excluding Milliken conductors; a maximum continuous conductor temperature not exceeding 90 °C. This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact. The object of this document is to define the type test methods and requirements which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused conductors.        
languageEnglish
titleIEC 61238-1-3num
titleCompression and mechanical connectors for power cables – Part 1-3: Test methods and requirements for compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) tested on non-insulated conducen
typestandard
page48
statusActive
treeIEC - International Electrotechnical Commission:;2018
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian