Show simple item record

IEEE Std 1017.3-2021 (Revision of IEEE Std 1019-2013)

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2022-07-04T20:39:52Z
date available2022-07-04T20:39:52Z
date copyright21 Jan. 2022
date issued2022
identifier other9690121.pdf
identifier urihttp://yse.yabesh.ir/std;quessioutho4703177793325273135A68A10958014A/handle/yse/312659
description abstractMinimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with polypropylene insulation, nitrile or polypropylene jacket, or metallic barrier or armor. These cables are for voltages not exceeding 8 kV (phase to phase) and conductor temperatures not exceeding 96 °C (205 °F) maximum or –10 °C (14 °F) minimum. Conductors, insulation, barrier(optional), assembly with or without jacket, and armor or encapsulating material, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.
languageEnglish
titleIEEE Recommended Practice for Specifying Electric Submersible Pump Cable--Polypropylene Insulationen
titleIEEE Std 1017.3-2021 (Revision of IEEE Std 1019-2013)num
typeStandard
page45
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2022
contenttypeFulltext
subject keywordsampacity ratings
subject keywordsESP
subject keywordscable construction
subject keywordsEPDM
subject keywordssubmersible pump cable
subject keywordsIEEE 1017.3™
subject keywordsESP cable
subject keywordsIEEE 1019™
subject keywordselectric submersible pump
subject keywordsassembly
subject keywordspolypropylene
subject keywordscable testing
subject keywordsethylene--propylene diene monomer
identifier DOI10.1109/IEEESTD.2022.9690121