IEEE - The Institute of Electrical and Electronics Engineers, Inc.: Recent submissions
Now showing items 561-580 of 2832
-
ISO/IEC/IEEE International Standard--Information technology--DevOps--Building reliable and secure systems including application build, package and deployment
Abstract: Technical principles and processes to build, package, and deploy systems and applications in a reliable and secure way are specified. Establishing effective compliance and information technology (IT) controls is the focus. ...Subject(s) : DevOps , continuous deployment , left-shift , IEEE 2675 , continuous delivery , agile , continuous integration , -
IEEE Recommended Practice for Quality Control Testing of External Discharges on Stator Coils, Bars, and Windings
Abstract: The procedure for quality control testing of external discharges on stator coils, bars, and windings of large air-cooled ac electric machines is described in this recommended practice.Subject(s) : IEEE 1799 , acoustic emission , stator winding , discharge inception voltage , electrical insulation , ac , external discharges , ultraviolet radiation , corona-imaging instrument , -
IEEE Guide for the Application of Capacitive Current Switching for AC High-Voltage Circuit Breakers Above 1000 V
Abstract: Guidance for the application of ac high-voltage circuit breakers switching capacitive currents is provided. The general theory of capacitive current switching and the notions of restrike, reignition, and nonsustained ...Subject(s) : overvoltages , restrike , application , nonsustained disruptive discharge , inrush current , IEEE C37.012 , capacitive current switching , NSDD , high-voltage circuit breakers , reignition , -
IEEE Standard for Ethernet Amendment 1: Power over Data Lines of Single Pair Ethernet
Abstract: This amendment to IEEE Std 802.3-2022 makes editorial and technical corrections, refinements, and clarifications to Clause 104 Power over Data Lines of Single Pair Ethernet, and related portions of the standard. No new to ...Subject(s) : copper , 10GBASE-T1 , IEEE 802.3 , 2.5GBASE-T1 , 5GBASET1 , PoDL , Ethernet , IEEE 802.3dd , 10BASE-T1L , 100BASE-T1 , 1000BASE-T1 , 10BASE-T1S , -
IEEE Recommended Practice for Software-Defined Networking (SDN) Based Middleware for Control and Management of Wireless Networks
Abstract: A software-defined networking (SDN) middleware is outlined in this recommended practice to support unified control and management of multiple radio access technology (multi-RAT ) wireless access networks for fifth generation ...Subject(s) : software-defined networking (SDN) , IEEE 802.22 WRAN , IEEE 1930.1 , network virtualization , IEEE 802.11 WLAN , fifth generation (5G) , -
IEEE Standard for Ethernet - Amendment 5: Enhancements to the MAC Merge and Time Synchronization Service Interface for Point-to-Point 10 Mb/s Single Pair Ethernet
Abstract: This amendment to IEEE Std 802.3-2022 specifies additions to and appropriate modifications of the IEEE Std 802.3 MAC Merge sublayer and the Time Synchronization Service Interface (TSSI) to support 10 Mb/s Single-Pair ...Subject(s) : copper , express traffic , IEEE 802.3 , IEEE 802.3cg , Ethernet , 10BASE-T1L , TSSI , 10BASE-T1S , preemption , IEEE 802.3de , -
IEEE Recommended Practice for Specifying Electric Submersible Pump Cable--Ethylene-Propylene Rubber Insulation
Abstract: Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethylene–propylene rubber ...Subject(s) : ampacity ratings , IEEE 1017.2™ , cable construction , EPDM , IEEE1018 , submersible pump cable , EPR , ESP cable , electric submersible pump , assembly , cable testing , -
IEEE Recommended Practice for Testing of Electric Submersible Pump Cable
Abstract: Procedures and test voltage values for factory, acceptance, and maintenance testing of electric submersible pump (ESP) cable systems are presented. This recommended practice applies to cable systems rated 3 kV through 8 ...Subject(s) : IEEE 1017 , cable testing , conductors , factory testing , field testing , cable maintenance , submersible pump cable , cable ampacity , electric submersible pump (ESP) , -
IEEE Standard for Testing and Performance of Optical Ground Wire (OPGW) for use on Electric Utility Power Lines - Redline
Abstract: The performance, test requirements, procedures, and acceptance criteria for a transmission line overhead ground wire (a.k.a. shield wire, static wire, earth wire, skywire) with optical fibers commonly known as optical ...Subject(s) : laboratory tests , type tests , optical ground wire , fiber optic ground wire , IEEE 1138 , OPGW , -
IEEE Standard for Security Management for Customer Cryptographic Assets on Cryptocurrency Exchanges
Abstract: In this standard requirements are defined for multiple aspects of security management for customer cryptographic assets on cryptocurrency exchanges, such as user identification using multi-factor authentication, prioritized ...Subject(s) : prioritized protection , IEEE 2140.2 , user identification , professional ethics of operation , security management , cryptocurrency exchanges , -
IEEE Guide for Maintenance Methods on Energized Power Lines
Abstract: General recommendations for performing maintenance work on energized power lines are provided. Technical explanations as required to cover certain laboratory testing of tools and equipment, in-service inspection, field ...Subject(s) : energized , maintenance , tools , power lines , equipment , IEEE 516 , -
IEEE/ISO/IEC International Standard-Telecommunications and exchange between information technology systems — Requirements for local and metropolitan area networks —Part 3: Standard for Ethernet AMENDMENT 3: Media access control parameters for 50 Gb/s and
Abstract: Clause 131 through Clause 140 and Annex 135A through Annex 136D are added to IEEE Std 802.3-2018 by this amendment to specify IEEE 802.3 Media Access Control (MAC) parameters, Physical Layer specifications, and management ...Subject(s) : amendment , 200 Gigabit Ethernet , 100GBASE-CR2 , 50GBASE-CR , 100GAUI-2 , 200GBASE-SR4 , 50GAUI-1 , forward error correction , 50 Gigabit Ethernet , 50GMII , 200GBASE-KR4 , 50GBASE-SR , 100GBASE-DR , 100GBASE-SR2 , IEEE 802.3cd™ , SMF , 50GBASE-LR , 50GBASE-KR , FEC , Ethernet , Energy-Efficient Ethernet , MMF , 100GBASE-KR2 , 50GBASE-FR , 100 Gigabit Ethernet , EEE , LAUI-2 , IEEE 802.3™ , 100GAUI-4 , 200GBASE-CR4 , 50GAUI-2 , -
IEEE Guide for Synchronization, Calibration, Testing, and Installation of Phasor Measurement Units (PMUs) for Power System Protection and Control - Redline
Abstract: Guidance for synchronization, calibration, testing, and installation of phasor measurement units (PMUs) applied in power systems is provided. The following are addressed in this guide: (a) considerations for the installation ...Subject(s) : PMU , phasor measurement unit , testing , GNSS , synchrophasor , calibration , IEEE C37.242 , -
IEEE/ISO/IEC International Standard-Telecommunications and exchange between information technology systems — Requirements for local and metropolitan area networks —Part 3: Standard for Ethernet AMENDMENT 1: Physical layer specifications and management par
Abstract: Ethernet Media Access Control (MAC) parameters, Physical Layer specifications, and management objects for the serial transfer of Ethernet format frames at 2.5 Gb/s and 5 Gb/s over electrical backplanes are defined in this ...Subject(s) : amendment , Energy Efficient Ethernet , Backplane Ethernet , 2.5GBASE-KX , AN , BASE-X , 5GBASE-R , IEEE 802.3 , EEE , 5GBASE-KR , 2.5GBASE-X , 2.5 Gigabit Ethernet , IEEE 802.3cb , Ethernet , BASE-R , Auto-Negotiation , 5 Gigabit Ethernet , -
IEEE/ISO/IEC-Telecommunications and exchange between information technology systems — Requirements for local and metropolitan area networks —Part 3: Standard for Ethernet AMENDMENT 2: Physical layer and management parameters for power over Ethernet over 4
Abstract: The maximum Powered Device (PD) power available is increased by this amendment to IEEE Std 802.3-2018 by utilizing all four pairs in the specified structured wiring plant. This represents a substantial change to the ...Subject(s) : amendment , DTE power via MDI , IEEE 802.3(TM) , PoE , Power over Ethernet , IEEE 802.3bt(TM) , Ethernet , -
IEEE Guide for Protecting Power Transformers
Abstract: Guidelines for protecting three-phase power transformers of more than 5 MVA rated capacity and operating at voltages exceeding 10 kV is provided to protection engineers and other readers in this guide. In some cases, a ...Subject(s) : grounding transformer , magnetizing inrush , volts-per-hertz protection , overcurrent protection , transformer protection , current transformer , IEEE C37.91 , regulating transformer , sudden pressure relay , gas accumulator relay , differential protection , transformer overexcitation , power transformer , -
IEEE/ISO/IEC International Standard - Software and systems engineering--Software testing--Part 4: Test techniques - Redline
Abstract: The purpose of this part of ISO/IEC/IEEE 29119 is to provide an International Standard that defines software test design techniques (also known as test case design techniques or test methods) that can be used within the ...Subject(s) : test methods , defines software test design techniques , systems engineering--software testing--part , software testing industry , test techniques - redline , test case design techniques , -
IEEE Standard Requirements, Terminology, and Test Code for Shunt Reactors Rated Over 500 kVA - Redline
Abstract: All liquid-immersed or dry-type, single-phase or three-phase, outdoor or indoor shunt reactors rated over 500 kVA are covered. Terminology and general requirements are stated, and the basis for rating shunt reactors is set ...Subject(s) : dry-type shunt reactor , liquid-immersed shunt reactor , dielectric tests , IEEE C57.21™ , -
IEEE Standard for Local and Metropolitan Area networks--Media Access Control (MAC) Service Definition-Amendment 1: Support for IEEE Std 802.15.3
Abstract: The Internal Sublayer Service for the IEEE 802.15.3 MAC entity is defined in this amendment.Subject(s) : Internal Sublayer Service , IEEE 802.1AC , ad-hoc network , IEEE 802.15.3 , wireless , multi-media , -
IEEE Guide for Energy Feedback System for DC Traction Power Supply System
Abstract: In the dc electric railways, when a train regenerates power, usually the power has to be consumed within the dc network because the dc traction power systems are often not reversible. Several technologies improve receptivity: ...Subject(s) : voltage stabilization , economic consideration , energy saving , modeling and simulation , energy feedback system , dc traction , IEEE 2657 ,