description abstractThis standard describes measurement and caiculation procedures for determining the diameters of u p right welded (laphutt) cylindrical tanks, or vertical Cylindrical tanks, with a smooth outside surface and either floating or íked roofs. This standard should be used in conjunction with API Standard 2550.
For external application of the ORLM on insulated tanks, the insulation must be removed. The ORLM may be used on the interior of the tank; however, when the reference circumference on the bottom course is established externally, the insdation at the bottom ring must be removed. This measurement shall conform to the procedures described in API Standard 2550.
Abnormally deformed tanks (that is, tanks that are dented or have other visible signs of damage) should be repaired before any calibration is undertaken.
languageEnglish
titleAPI MPMS 2.2Bnum
titleManual of Petroleum Measurement Standards Chapter 2 - Tank Calibration Section 2B - Calibration of Upright Cylindrical Tanks Using the Optical Reference Line Method - First Editionen
typestandard
page14
statusActive
treeAPI - American Petroleum Institute:;2007
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record