Show simple item record

CABLE AND CABLE ASSEMBLIES, SPECIAL PURPOSE, ELECTRICAL, MAGNETIC MINESWEEPING, GENERAL SPECIFICATION FOR

contributor authorNAVY - SH - Naval Sea Systems Command (Ship Systems)
date accessioned2017-09-04T16:38:05Z
date available2017-09-04T16:38:05Z
date copyright33165
date issued1990
identifier otherVHLVDAAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/101674
description abstractThis specification covers the requirements for fabrication and test of cables and cable assemblies for magnetic minesweeping.
Magnetic minesweeping cables are classified as follows:
     P1 Cable - Insulated, nonbuoyant.      P2 Cable - Insulated, nonbuoyant.      P3 Cable - Insulated, nonbuoyant.      A1 Cable - Insulated, buoyant.      A2 Cable - Insulated, buoyant.      A3 Cable - Insulated, buoyant.      S2 Cable - Insulated, single conductor, buoyant.      S3 Cable - Insulated, single conductor, buoyant.      K4 Cable - Noninsulated, single conductor, nonbuoyant.


Cables are to be in the standard lengths shown in table I (see 6.2). Cables are to be manufactured in sufficient lengths to allow removal of the test samples specified in 4.5.2.1, 4.5.2.2 and 4.5.2.3 without reducing the remaining cable length below the length shown in table I. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Naval Sea Systems Command, SEA 55Z3, Department of the Navy, Washington, DC 20362-5101 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. TABLE I. Standard lengths.
Tolerance                                  (percent)                               -----------------    Cable     Length(feet)      Plus     Minus -----------------------------------------------       P1          70 1/           5        0      P2         100 1/           5        0      P3         130 1/           5        0      Al         675 2/           2        1      A2         675 2/           2        1      A3         675 2/           2        1      S2         900 2/           2        2      S3         900 2/           2        2      K4         150              2        2  1/ See specification sheets for specific requirements. 2/ Exclusive of flexible copper conductor terminals     (pigtails).


Cable assemblies are of the following types as specified (see 6.2):
       Type 1 Assembly - One 70 foot P1 section, one 675 foot A1 section, and                           one 150 foot K4 section.        Type 2 Assembly - One 100 foot P2 section, one 675 foot A2 section, and                           one 150 foot K4 section.        Type 3 Assembly - One 130 foot P3 section, one 675 foot A3 section, and                           one 150 foot K4 section.        Type 2 Single assembly (S2 assembly) - One 900 foot S2 section and one                                                150 foot K4 section.        Type 3 Single assembly (S3 assembly) - One 900 foot S3 section and one                                                150 foot K4 section.


Intended Use: The cables described in this specification are intended for use during magnetic minesweeping.
languageEnglish
titleMIL-C-17694Hnum
titleCABLE AND CABLE ASSEMBLIES, SPECIAL PURPOSE, ELECTRICAL, MAGNETIC MINESWEEPING, GENERAL SPECIFICATION FORen
typestandard
page22
statusActive
treeNAVY - SH - Naval Sea Systems Command (Ship Systems):;1990
contenttypefulltext
subject keywordsSheath
subject keywordsvulcanized
subject keywordsTerminal