IEEE - The Institute of Electrical and Electronics Engineers, Inc.: Recent submissions
Now showing items 1081-1100 of 2832
-
IEEE Standard for Requirements for Time Tags Created by Intelligent Electronic Devices--COMTAG
Abstract: Common requirements for associating time tags with data items recorded or transmitted by Intelligent Electronic Devices (IEDs) are established in this standard. Time tag attributes and requirements for describing time tag ...Subject(s) : COMTAG , IED , IEEE C37.237 , IRIG-B , time stamp , time synchronization , time tag , IEEE Standards , Tagging , Smart devices , Intelligent systems , Synchronization , Timing , Electronic equipment , -
IEEE Standard for AC High Voltage Circuit Switchers Rated 15.5 kV through 245 kV
Abstract: This standard is applicable to ac circuit switchers designed for outdoor installation and for rated power frequencies of 50 Hz and 60 Hz and rated maximum voltages of 15.5 kV through 245 kV. It is applicable only to ...Subject(s) : circuit switcher , coordinated disconnect , design tests , IEEE C37.016 , interrupter , operating mechanism , primary-bus fault , production tests , ratings , service conditions , stored energy , transformer-limited fault , transient recovery voltage , IEEE Standards , Interrupters , Fault diagnosis , Energy storage , Power transformers , Transient analysis , Voltage control , Switching systems , -
ISO/IEC/IEEE International Standard - Software engineering - Recommended practice for software acquisition
Abstract: A set of useful quality considerations that can be selected and applied during one or more steps in a software acquisition process is described in this recommended practice. The recommended practices can be applied to ...Subject(s) : acquirer , custom developed , end user , FOSS , IEEE 1062(TM) , off-the-shelf , OTS , SaaS , software acquisition process , software as a service , supplier , IEEE Standards , IEC Standards , ISO Standards , Software engineering , -
IEC/IEEE International Standard - High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers for alternating current systems up to and including 38 kV
Subject(s) : PC37.60 , IEC P62271-11 , HIGH-VOLTAGE SWITCHGEAR , CONTROLGEAR , IEEE Standards , IEC Standards , Switchgear , High-voltage techniques , Control systems , Voltage control , -
IEEE Recommended Practice for Electrical Installations on Shipboard--Marine Sectors and Mission Systems
Abstract: Recommendations for the grouping of ships and their predominant mission systems to define and highlight unique features and requirements of a ship’s electrical power system driven by the ship’s mission for classification ...Subject(s) : IEEE 45.4 , marine electrical engineering , marine vessels , naval vessels , shipboard electrical systems , ships , IEEE Standards , Electrical equipment , Marine vehicles , Marine transportation , Electrical engineering , -
American National Standard Performance Requirements for Spectroscopic Personal Radiation Detectors (SPRDs) for Homeland Security
Abstract: Design and performance requirements, along with testing methods, for evaluating radiation detection instruments that are pocket-sized and worn on the body for the purpose of rapid detection and identification of radioactive ...Subject(s) : alarm , ANSI N42.48 , design criteria , exposure rate , performance specifications , personal radiation detectors , pocket-sized , radiation , radiation detection , radiation instrumentation , spectroscopic , ANSI Standards , Spectroscopy , Radiation detectors , Radiation monitoring , Performance evaluation , -
IEEE Standard for Authenticated Encryption with Length Expansion for Storage Devices
Abstract: Cryptographic and data authentication procedures for storage devices that support length expansion, such as tape drives, are specified. Such procedures include the following cryptographic modes of operation for the AES ...Subject(s) : authentication , CBC , CCM , cryptography , data storage , encryption , GCM , HMAC , IEEE 1619.1(TM) , security , tape drive , variable-length block , XTS , IEEE Standards , Authentication , Security , Encryption , Data storage systems , -
American National Standard for Performance Criteria for Spectroscopy-Based Portal Monitors Used for Homeland Security
Abstract: Amendment 1 addresses an observation made by a user of the standard. The observation raised a concern that misunderstandings may occur due to the common use of “tn†for other calculations. To address the concern, “tn†...Subject(s) : ANSI N42.38 , portal monitor , spectrometric , spectroscopy , ANSI Standards , Spectroscopy , Performance evaluation , Radiation monitoring , Radiation detectors , -
IEEE Standard for Inverse-Time Characteristics Equations for Overcurrent Relays
Abstract: The inverse-time characteristics of overcurrent relays are defined in this standard. Operating equations and allowances are provided in the standard. The standard defines an integral equation for microprocessor relays that ...Subject(s) : inverse-time characteristics , overcurrent relays , IEEE Standards , Power system relaying , Relays , Switchgear , -
IEEE Standard for Cryptographic Protection of Data on Block-Oriented Storage Devices
Abstract: Cryptographic transform for protection of data in sector-level storage devices is specified in this standard.Subject(s) : data-at-rest security , encryption , IEEE 1619 , security , storage , XTS , IEEE Standards , Data storage systems , Security , Encryption , Cyrptography , -
IEEE Standard for Ethernet - Amendment 1:Physical Layer Specifications and Management Parameters for 2.5 Gb/s and 5 Gb/s Operation over Backplane
Abstract: Ethernet Media Access Control (MAC) parameters, Physical Layer specifications, and management objects for the serial transfer of Ethernet format frames at 2.5 Gb/s and 5 Gb/s over electrical backplanes are defined in this ...Subject(s) : 2.5 Gigabit Ethernet , 5 Gigabit Ethernet , 2.5GBASE-KX , 2.5GBASE-X , 5GBASE-KR , 5GBASE-R , amendment , AN , Auto-Negotiation , Backplane Ethernet , BASE-R , BASE-X , EEE , Energy Efficient Ethernet , Ethernet , IEEE 802.3 , IEEE 802.3cb , IEEE Standards , Ethernet , Physical layer , Telecommunication network management , Energy efficiency , -
IEEE Guide for Evaluating and Testing the Electrical Performance of Energy Saving Devices
Abstract: Described in this guide are methods to evaluate and test the electrical performance of energy saving devices (ESDs). Measurement methods that focus on monitoring the power consumed or generated by the observed load or ...Subject(s) : electrical energy consumption , electrical test protocol , energy saving device , ESD , IEEE 1889(TM) RESD , retrofit energy saving device , IEEE Standards , Energy consumption , Power measurement , Power electronics , Energy conservation , -
IEEE Guide for Performing Arc-Flash Hazard Calculations - Redline
Abstract: This guide provides mathematical models for designers and facility operators to apply in determining the arc-flash hazard distance and the incident energy to which workers could be exposed during their work on or near ...Subject(s) : arc blast , arc fault currents , arc flash , arc-flash boundary , arc-flash hazard , arc-flash hazard analysis , arc-flash hazard marking , arc in enclosures , arc in open air , electrical hazard , IEEE 1584â„¢ , incident energy , personal protective equipment , PPE , protective device coordination study , short-circuit study , working distances , IEEE Standards , Arc discharges , Hazards , Energy management , Fault diagnosis , -
IEEE Standard for Radio-Frequency Energy and Current-Flow Symbols - Redline
Abstract: Symbols to inform people about the presence of potentially hazardous levels of radiofrequency energy or the presence of contact current hazards in the frequency range of 3 kHz to 300 GHz are specified in this standard. ...Subject(s) : caution , contact current , danger , hazard , IEEE C95.2â„¢ , labels , microwave , radiofrequency , shock , signs , symbol , warning , IEEE Standards , Hazards , Radio frequency , Microwave communication , Symbols , -
IEEE Standard for Ethernet - Redline
Abstract: Ethernet local area network operation is specified for selected speeds of operation from 1 Mb/s to 400 Gb/s using a common media access control (MAC) specification and management information base (MIB). The Carrier Sense ...Subject(s) : 2.5 Gigabit Ethernet , 5 Gigabit Ethernet , 10 Gigabit Ethernet , 25 Gigabit Ethernet , 40 Gigabit Ethernet , 100 Gigabit Ethernet , 200 Gigabit Ethernet , 400 Gigabit Ethernet , attachment unit interface , AUI , Auto-Negotiation , Backplane Ethernet , data processing , DTE Power via the MDI , Energy Efficient Ethernet , EPoC , EPON , EPON Protocol over Coax , Ethernet , Ethernet in the First Mile , Ethernet passive optical network , express traffic , Fast Ethernet , Gigabit Ethernet , IEEE 802.3 , information exchange , LAN , local area network , management , MDI , medium dependent interface , media independent interface , MIB , MII , MPMC , multi-point MAC control , PCS , PHY , physical coding sublayer , Physical Layer , physical medium attachment , physical medium dependent , PMA , PMD , PoDL , Power over Data Lines , Power over Ethernet , reconciliation sublayer , repeater , RS , type field , VLAN tag , IEEE Standards , Ethernet , Data processing , Local area networks , Metropolitan area networks , -
IEEE Standard for Performance Characteristics and Dimensions for Power Transformer and Reactor Bushings
Abstract: Electrical, dimensional, and related requirements for power transformer and reactor bushings that have basic impulse insulation levels (BILs) of 150 kV and above are covered. Specific values for dimensional and related ...Subject(s) : basic impulse insulation levels , BILs , cantilever test , capacitance , creepage distance , flashover , IEEE Std C57.19.01â„¢ , line-to-ground voltage , nominal system voltage , power factor , power reactor bushings , power transformer bushings , IEEE Standards , Capacitance , Reactors , Power transformers , Insulation , Voltage control , -
IEEE Recommended Practice for Personnel Qualifications for Installation and Maintenance of Stationary Batteries - Redline
Abstract: The areas of recommended knowledge for installers and maintainers of stationary batteries and related systems, to the extent that they affect the battery, are defined in this recommended practice. Design of the dc system ...Subject(s) : battery , certification , classroom , competent , course , curriculum , education , experience , IEEE 1657â„¢ , inspect , install , instruct , knowledge , level , maintenance , monitor , preventative , proactive , proficient , qualification , routine , service , skill , student , teach , technician , test , IEEE Standards , Maintenance engineering , Batteries , Energy storage , -
IEEE Standard for Requirements for Conversion of Power Switchgear Equipment - Redline
Abstract: Directions and requirements are provided for the conversion of qualified power switchgear equipment. Examples such as low-voltage power circuit breakers; high-voltage outdoor, and medium-voltage indoor drawout power circuit ...Subject(s) : circuit breakers , compartment adapter , conversion , definite-purpose switching device , IEEE C37.59â„¢ , interrupters , modular assembly , power switchgear equipment , qualified design , remote racking device , retrofill , retrofit , switchgear , vacuum , IEEE Standards , Switchgear , Power conversion , Circuit breakers , -
IEEE Guide for Protective Relay Application to Transmission-Line Series Capacitor Banks - Redline
Abstract: The application of protective relays on transmission-line series capacitor banks is covered. Ample discussion of the protection and control issues related to series capacitor bank installations is provided to the reader. ...Subject(s) : bypass gap , bypass switch , externally fused capacitor , fuseless capacitor , harmonic protection , IEEE C37.116â„¢ , internally fused capacitor , metal oxide varistor , MOV , series capacitor , unbalance protection , IEEE Standards , Power transmission lines , Capacitors , Harmonic analysis , Transmission lines , Protective relaying , -
IEEE Recommended Practice for the Design of Buswork Located in Seismically Active Areas - Redline
Abstract: Recommended practices for the engineering and design of flexible and rigid bus connections for bus and equipment in electric power substations located in seismically active areas are provided in this document.Subject(s) : bus , buswork , conductor , connections , earthquakes , electrical equipment , flexible bus , flexible buswork , IEEE 1527â„¢ , interconnected equipment , interconnection , rigid bus , rigid buswork , seismic , seismic design , slack , substations , IEEE Standards , Earthquakes , Seismic measurements , Electronics equipment , Substations ,