IEEE - The Institute of Electrical and Electronics Engineers, Inc.: Recent submissions
Now showing items 1161-1180 of 2832
-
IEEE Guide for Liquid-Immersed Transformers Through-Fault-Current Duration
Abstract: Recommendations believed essential for the application of overcurrent protective devices applied to limit the exposure time of transformers to short circuit current are set forth. Transformer coordination curves are presented ...Subject(s) : IEEE C57.109â„¢ , liquid-immersed transformer , transformer , IEEE Standards , Power transformers , Liquid cooling , Immersion cooling , -
ISO/IEC/IEEE International Standard - Information Technology--Portable Operating System Interface (POSIX(R))-- Technical Corrigendum 2
Abstract: Problems discovered since the approval of IEEE Std 1003.1-2008 and IEEE Std 1003.1-2008/Cor 1-2013 are addressed.Subject(s) : API , application program interface , argument , asynchronous , basic regular expression , batch job , batch system , BRE , built-in utility , byte , child , command language interpreter , CPU , ERE , extended regular expression , FIFO , file access control mechanism , IEEE 1003.1(TM) , input/output , I/O , job control , network , portable operating system interface , POSIX(R) , IEEE Standards , ISO Standards , IEC Standards , Operating systems , Information technology , Application programming interfaces , -
IEEE Standard for Discovery, Authentication, and Authorization in Host Attachments of Storage Devices
Abstract: Discovery, authentication, and authorization protocols between hosts and storage devices over multiple transports are defined in this standard.Subject(s) : authentication , authorization , CF , CompactFlash(R) , discovery , e*MMC , IEEE 1667(TM) , NVMe , NVM Express , password silo , probe silo , SAS , SATA , SCSI , SCTS , security , SILO , smart card transport silo , STID , storage , TCG storage transport silo , transport independent , trusted computing group , UAS , UFS , USB , USB BOT , IEEE Standards , Data storage systems , Authentication , -
ISO/IEEE International Standard for Health informatics -- Point-of-care medical device communication -- Part 20702: Medical devices communication profile for web services
Abstract: Within the context of the ISO/IEEE 11073 family of standards for point-of-care (PoC)medical device communication, a communication protocol specification for a distributed system of PoC medical devices and medical IT systems ...Subject(s) : Keywords: Devices Profle for Web Services , DPWS , Eicient XML Interchange , EXI , IEEE 11073-20702â„¢ , ISO/IEEE 11073 , MDC , medical device communication , PoC , point-of-care , safety , Simple Object Access Protocol , SOAP , Streaming Web Services , WS-Discovery , IEEE Standards , ISO Standards , XML , Medical devices , Media streaming , Point of care , Knowledge discovery , Safety , -
IEEE Standard for Local and metropolitan area networks--Bridges and Bridged Networks--Amendment 30: YANG Data Model
Abstract: A YANG data model in support of configuration and operational status information for a subset of Bridging capabilities is provided in this amendment to IEEE Std 802.1Qâ„¢-2018. (The PDF of this standard is available at no ...Subject(s) : Bridged Local Area Networks , local area networks (LANs) , MAC Bridges , metropolitan area networks , Virtual Bridged Local Area Networks (virtual LANs) , YANG. , IEEE Standards , Local area networks , Metropolitan area networks , Media Access Protocol , Bridge circuits , Virtualization , -
IEC/IEEE International Standard - Power transformers - Part 16: Transformers for wind turbine applications
Subject(s) : IEEE Standards , IEC Standards , Power transformers , Wind turbines , Wind power generation , -
IEEE Approved Draft Standard for Local and Metropolitan Area Networks - Port-Based Network Access Control Amendment: YANG Data Model
Abstract: This amendment specifies a YANG data model that allows configuration and status reporting for port-based network access control in the scenarios described in Clause 7 of this standard and Clause 11 of IEEE Std 802.1AE(TM), ...Subject(s) : authorized port , confidentiality , data model , data origin authenticity , information model , integrity , LANs , local area networks , MAC Bridges , MAC security , MAC Service , MANs , metropolitan area networks , port based network access control , secure association , security , transparent bridging , YANG. , IEEE Standards , Local area networks , Metropolitan area networks , Data models , Access control , -
IEEE Recommended Practice for Conducting Harmonic Studies and Analysis of Industrial and Commercial Power Systems
Abstract: Harmonic studies and analysis of industrial and commercial power systems are described. The basic concepts involved in such studies are described first. This is followed by a discussion of how to determine the need for a ...Subject(s) : commercial power system , harmonics , harmonic analysis , harmonic analysis methods , harmonic analysis tools , harmonic distortion , harmonic filters , harmonic frequency scan , harmonic impedance , harmonic limits , harmonic load flow , harmonic mitigation , harmonic power flow study , harmonic sources , harmonic studies , IEEE 3002.8â„¢ , industrial and commercial power systems , industrial power system , interharmonics , resonance , system modeling , IEEE Standards , Harmonic analysis , Resonance , Industrial power systems , -
IEEE Standard for Definitions for AC High-Voltage Air Switches Rated Above 1000 V
Subject(s) : definitions , IEEE Std C37.30.5â„¢ , terms , IEEE Standards , Switchgear , AC motors , Power systems , Circuit faults , Voltage control , -
IEEE Standard for Ethernet
Abstract: Ethernet local area network operation is specified for selected speeds of operation from 1 Mb/s to 400 Gb/s using a common media access control (MAC) specification and management information base (MIB). The Carrier Sense ...Subject(s) : 2.5 Gigabit Ethernet , 5 Gigabit Ethernet , 10 Gigabit Ethernet , 25 Gigabit Ethernet , 40 Gigabit Ethernet , 100 Gigabit Ethernet , 200 Gigabit Ethernet , 400 Gigabit Ethernet , attachment unit interface , AUI , Auto-Negotiation , Backplane Ethernet , data processing , DTE Power via the MDI , Energy Efficient Ethernet , EPoC , EPON , EPON Protocol over Coax , Ethernet , Ethernet in the First Mile , Ethernet passive optical network , express traffic , Fast Ethernet , Gigabit Ethernet , IEEE 802.3 , information exchange , LAN , local area network , management , MDI , medium dependent interface , media independent interface , MIB , MII , MPMC , multi-point MAC control , PCS , PHY , physical coding sublayer , Physical Layer , physical medium attachment , physical medium dependent , PMA , PMD , PoDL , Power over Data Lines , Power over Ethernet , reconciliation sublayer , repeater , RS , type field , VLAN tag , IEEE Standards , Ethernet , Local area networks , Metropolitan area networks , Energy efficiency , Passive optical networks , -
IEEE Standard for Information technology--Telecommunications and information exchange between systems Local and metropolitan area network--Specific requirements Part 11: Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications Amen
Abstract: Modifications to IEEE Std 802.11â„¢-2016, above the physical layer (PHY), to enable delivery of preassociation service discovery information to IEEE 802.11 stations (STAs) are defined in this amendment., above the physical ...Subject(s) : amendment , bloom filter , hash function , IEEE 802.11â„¢ , IEEE 802.11aqâ„¢ , preassociation , service discovery , IEEE Standards , Information technology , Information exchange , Wireless LAN , Media Access Protocol , Physical layer , -
IEEE Standard for Requirements for Conversion of Power Switchgear Equipment
Abstract: Directions and requirements are provided for the conversion of qualified power switchgear equipment. Examples such as low-voltage power circuit breakers; high-voltage outdoor, and medium-voltage indoor drawout power circuit ...Subject(s) : circuit breakers , compartment adapter , conversion , definite-purpose switching device , IEEE C37.59â„¢ , interrupters , modular assembly , power switchgear equipment , qualified design , remote racking device , retrofill , retrofit , switchgear , vacuum , IEEE Standards , Trademarks , Circuit breakers , Medium voltage , Interrupters , -
IEEE Standard for a Real-Time Operating System (RTOS) for Small-Scale Embedded Systems
Abstract: A real-time operating system (RTOS) called μT-Kernel for small-scale embedded systems such as systems with a single chip microcomputer including 16-bit CPUs, systems with a small amount of ROM/RAM, and systems without a ...Subject(s) : 16-bit CPU , alarm handler , API , Application Programming Interface , cyclic handler , device management , embedded , event flag , fast lock , fast multi-lock , IEEE 2050™ , interrupt handler , kernel , IoT edgenode , mailbox , memory pool , message buffer , mutex , non-task portion , physical timer , power management , power saving , priority-based , quasi-task portion , real time , real-time operating system (RTOS) , semaphore , service profile , single chip microcomputer , single chip micro-controller , small scale , system call , task , task dispatching , task portion , task independent portion , task scheduling , TRON , μT-Kernel , IEEE Standards , Real-time systems , Task analysis , Embedded systems , Consumer electronics , -
IEEE Standard for the Testing of Microgrid Controllers
Subject(s) : compliance testing , core functions , dispatch , distributed energy resources , distributed energy storage , distributed generation , electric distribution systems , energy management system , grid-connected , IEEE 2030.8â„¢ , initiating event , interconnection agreement , interconnection requirements , islanded , microgrid , microgrid controller , microgrid control system (MGCS) , microgrid system , planned islanding , point of interconnection (POI) , power quality , reconnection , ride through , standards , steady state (SS) , transition , unplanned islanding , IEEE Standards , Microgrids , Controllers , Energy storage , Resource management , Power quality , Power control , -
IEEE Industry Connections (IEEE-IC) Personalized Digital Last (a Women s Example)--The Tool Required to Enable Mass Customization
Abstract: This white paper examines the development of a personalized digital last and the impact on the role of footwear technicians. As the personalized digital last becomes the basis of future footwear production, the role of ...Subject(s) : Production , Footwear , Digital systems , Mass customization , Manufacturing , Marketing management , -
IEEE Recommended Practice for the Design of Buswork Located in Seismically Active Areas
Abstract: Recommended practices for the engineering and design of flexible and rigid bus connections for bus and equipment in electric power substations located in seismically active areas are provided in this document.Subject(s) : bus , buswork , conductor , connections , earthquakes , electrical equipment , flexible bus , flexible buswork , IEEE 1527â„¢ , interconnected equipment , interconnection , rigid bus , rigid buswork , seismic , seismic design , slack , substations , IEEE Standards , Substations , Seismic measurements , Earthquake engineering , Power system reliability , -
IEEE Standard for Local and Metropolitan Area Networks - Secure Device Identity
Abstract: A Secure Device Identifier (DevID) is cryptographically bound to a device and supports authentication of the device’s identity. An Initial Device Identifier (IDevID) provide by the supplier of a device can be supplemented ...Subject(s) : access control , authentication , authorization , certificate , IEEE 802.1AR , LANs , local area networks , MAC security , MANs , metropolitan area networks , PKI , port-based network access control , secure association , Secure Device Identifier , security , X.509 , IEEE Standards , Local area networks , Metropolitan area networks , Network security , Access control , Media Access Protocol , Authentication , -
IEEE Standard Test Specifications for Surge-Protective Devices (SPDs) for Use on the Load Side of the Service Equipment in Low-Voltage (1000 V and Less) AC Power Circuits
Abstract: Recommended practices for the engineering and design of flexible and rigid bus connections for bus and equipment in electric power substations located in seismically active areas are provided in this document.Subject(s) : C62.62 , bus , buswork , conductor , connections , earthquakes , electrical equipment , flexible bus , flexible buswork , IEEE 1527â„¢ , interconnected equipment , interconnection , rigid bus , rigid buswork , seismic , seismic design , slack , substations , IEEE Standards , Seismic measurements , Substations , Earthquakes , Equipment , Power system reliability , -
IEEE Guide for the Use of IEEE Std 1641(TM), IEEE Standard for Signal and Test Definition Amendment 1: Addition of Guidelines for Producing Reusable Test Signal Frameworks for Use on Platforms Utilizing Automatic Test Markup Language
Abstract: Amend the guide to add guidelines for producing reusable TSFs for use on platforms utilizing ATML, and produce example TSFs showing conformance with the guidelines. This guide explains how signal definitions and test ...Subject(s) : ATLAS , IEEE 1641.1â„¢ , TSF Library , IEEE Standards , XML , Markup languages , Testing , -
IEEE Guide for Acceptance and Maintenance of Natural Ester Insulating Liquid in Transformers
Abstract: Assistance to equipment manufacturers and service companies to evaluate the suitability of unused natural ester insulating liquids being received from suppliers is provided in this guide. Information for transformer operators ...Subject(s) : dielectric coolant , high fire point liquid , IEEE C57.147â„¢ , insulating liquid , less flammable liquid , natural ester liquid , transformer , vegetable oil , IEEE Standards , Dielectrics , Power transformers , Liquid cooling , Oil insulation ,

درباره ما