Show simple item record

Effect of various arrangements of triangular ledges on the performance of a 23 degree conical diffuser at subsonic Mach numbers

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T16:57:56Z
date available2017-09-04T16:57:56Z
date copyright01/01/1954
date issued1954
identifier otherBWONEEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/121335
description abstractA brief investigation has been made to determine whether the use of annular ledges to promote turbulent momentum exchange will improve the performance of a short, wide-angle diffuser. Results are presented of tests of a 23º conical diffuser with a 2:1 ratio of exit to inlet area with both rough and smooth triangular ledges, approximately one-tenth of the inlet boundary-layer thickness in height, installed in succession from the inlet to the exit. The results show that, although the flow in the diffuser without ledges was very unstable, the presence of a roughness strip near the inlet, with or without additional ledges, assured stable flow. For the configurations investigated, the static-pressure recovery and the total-pressure-loss coefficient were either unaffected or only slightly impaired by the installation of the ledges.
languageEnglish
titleNACA-TM-3123num
titleEffect of various arrangements of triangular ledges on the performance of a 23 degree conical diffuser at subsonic Mach numbersen
typestandard
page37
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1954
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record