description abstractDescription of Driving Event:
During servicing of the oxidizer on the forward reaction control system (FRCS), a ground half quick disconnect (QD) failed. The failure mode was such that an open flow path was created to the outside of the QD and 15 to 20 gallons of oxidizer (N2O4) flowed overboard prior to isolating the flow sources. The failure of the ground-half QD was attributed to an accumulation of iron nitrate lodged between the probe and the dynamic head. The presence of iron nitrate was traced to contaminated fuel.
languageEnglish
titleNASA-LLIS-0055num
titleLessons Learned - Quick Disconnect F.O.D.; Quick Disconnect (QD) Design; SCAPE Operationsen
typestandard
page3
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1992
contenttypefulltext
subject keywordsEmergency Preparedness
subject keywordsEnergetic Materials - Explosive/Propellant/Pyrotechnic
subject keywordsFire Protection
subject keywordsFlight Equipment
subject keywordsGround Equipment
subject keywordsGround Operations
subject keywordsHardware
subject keywordsHazardous/Toxic Waste/Materials
subject keywordsLaunch Process
subject keywordsLaunch Vehicle
subject keywordsPackaging Handling Storage
subject keywordsParts Materials & Processes
subject keywordsPersonal Protective Equipment
subject keywordsSpacecraft


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record