Show simple item record

MICROCIRCUIT, HYBRID, LINEAR, 12 VOLT, DUAL CHANNEL, DC/DC CONVERTER, NONISOLATED

contributor authorDLA - CC - DLA Land and Maritime
date accessioned2017-09-04T17:18:40Z
date available2017-09-04T17:18:40Z
date copyright06/28/1996
date issued1996
identifier otherZLJAEAAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/141950
description abstractThis drawing forms a part of a one part - one part number documentation system (see 6.6 herein). This drawing describes device requirements for hybrid microcircuits to be processed in accordance with MIL-PRF-38534. Two product assurance classes, military high reliability (device class H) and space application (device class K) and a choice of case outlines and lead finishes are available and are reflected in the Part or identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN.
The PIN shall be as shown in the following example: CHART
Device classes H and K RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device.
The device type(s) shall identify the circuit function as follows:
    Device type          Generic number               Circuit function          01                MCH2812DN       DC-DC converter, nonisolated, 1.5 W, ±12 V output


This device class designator shall be a single letter identifying the product assurance level as follows:
    Device class                 Device requirements documentation      H or K              Certification and qualification to MIL-PRF-38534


The case outline(s) shall be as designated in MIL-STD-1835 and as follows:
    Outline letter       Descriptive designator    Terminals               Package style             X                  See figure 1              7                    Dual-in-line


The lead finish shall be as specified in MIL-PRF-38534 for classes H and K. Finish letter "X"shall not be marked on the microcircuit or its packaging. The "X" designation is for use in specifications when lead finishes A, B, and C are considered acceptable and interchangeable without preference.
  Input voltage range.............................     −0.5 V dc to +50 V dc   Power dissipation (PD)..........................     4.2 W   Output power....................................     1.56 W   Lead temperature soldering, (10 seconds)........     +300°C   Storage temperature range.......................     −65°C to +150°C


  Input voltage range...................................     +12 V dc to +50 V dc   Case operating temperature range (TC).................     −55°C to +125°C


Intended Use: Microcircuits conforming to this drawing are intended for use for Government microcircuit applications (original equipment), design applications, and logistics purposes.
languageEnglish
titleSMD-5962-95706num
titleMICROCIRCUIT, HYBRID, LINEAR, 12 VOLT, DUAL CHANNEL, DC/DC CONVERTER, NONISOLATEDen
typestandard
page12
statusActive
treeDLA - CC - DLA Land and Maritime:;1996
contenttypefulltext


Files in this item