Show simple item record

English -- Electromagnetic compatibility (EMC) – Part 4-34 :Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current more than 16 A per phase - First Edition;
French -- Compatibilité électromagnétique (CEM) – Partie 4-34: Techniques d'essai et de mesure – Essais d'immunité aux creux de tension coupures brèves et variations de tension pour matériel ayant un courant appelé de plus de 16 A par phase - First Edition

contributor authorCSA - CSA Group
date accessioned2017-09-04T18:00:56Z
date available2017-09-04T18:00:56Z
date copyright2006.05.01 (R 2011)
date issued2011
identifier otherFXXCDFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/183944
description abstractThis part of IEC 61000 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations.
This standard applies to electrical and electronic equipment having a rated input current exceeding 16 A per phase. It covers equipment installed in residential areas as well as industrial machinery, specifically voltage dips and short interruptions for equipment connected to either 50 Hz or 60 Hz a.c. networks, including 1-phase and 3-phase mains.
NOTE 1 Equipment with a rated input current of 16 A or less per phase is covered by publication IEC 61000-4-11.
NOTE 2 There is no upper limit on rated input current in this publication. However, in some countries, the rated input current may be limited to some upper value, for example 75 A or 250 A, because of mandatory safety standards.
It does not apply to electrical and electronic equipment for connection to 400 Hz a.c. networks. Tests for equipment connected to these networks will be covered by future IEC standards.
The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to voltage dips, short interruptions and voltage variations.
NOTE 1 Voltage fluctuations are covered by publication IEC 61000-4-14.
NOTE 2 For equipment under test with rated currents above 250 A, suitable test equipment may be difficult to obtain. In these cases, the applicability of this standard should be carefully evaluated by committees responsible for generic, product and product-family standards. Alternatively, this standard might be used as a framework for an agreement on performance criteria between the manufacturer and the purchaser.
The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of equipment or a system against a defined phenomenon. As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for defining the appropriate test levels. Technical committee 77 and its subcommittees are prepared to co-operate with products
languageEnglish, French
titleCSA CAN/CSA-CEI/IEC 61000-4-34:06num
titleEnglish -- Electromagnetic compatibility (EMC) – Part 4-34 :Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current more than 16 A per phase - First Editionen
titleFrench -- Compatibilité électromagnétique (CEM) – Partie 4-34: Techniques d'essai et de mesure – Essais d'immunité aux creux de tension coupures brèves et variations de tension pour matériel ayant un courant appelé de plus de 16 A par phase - First Editionother
typestandard
page76
statusActive
treeCSA - CSA Group:;2011