Show simple item record

UL Standard for Safety Electrical Equipment for Laboratory Use; Part 2: Particular Requirements for Laboratory Atomic Spectrometers with Thermal Atomization and Ionization - First Edition

contributor authorUL - UL
date accessioned2017-09-04T18:30:52Z
date available2017-09-04T18:30:52Z
date copyright04/10/2002
date issued2002
identifier otherIXHVXAAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/213080
description abstractThis International Standard applies to electrically powered laboratory atomic spectrometers with thermal atomization.
NOTE - Examples include atomic absorption spectrometers, emission flame photometers, atomic fluorescence spectrophotometers, inductively coupled plasma spectrometers, microwave coupled plasma spectrometers, and mass spectrometers, all with thermal atomization and ionization (including tubing and connectors which are provided by the manufacturer for connection to external supplies).
This Part 1 of the standard does not cover:
– reliable function, performance or other properties of the equipment;
– effectiveness of transport and packaging;
– servicing (repair);
– protection of servicing (repair) personnel.
NOTE – Servicing personnel are expected to be reasonably careful in dealing with obvious hazards, but the design should protect against mishap by the use of warning labels, shields for hazardous voltage TERMINALS, segregation of low-voltage circuits from hazardous voltages, etc. More important, servicing personnel should be trained against unexpected hazards.
Equipment excluded from scope
This Part 1 does not apply to:
– electric power equipment, for example power electronics;
– machine TOOLS and their controls (see IEC 204);
– Class 0, 5, 1 and 2 alternating current watt-hour meters (see IEC 521);
– medical electrical equipment within the scope of IEC 601;
– biological amplifies which link humans to equipment in research or teaching contexts;
– TYPE-TESTED and partially TYPE-TESTED assemblies of low-voltage switchgear and controlgear (see IEC 439-1);
– circuits and equipment which are part of the building electrical installation (see IEC 364);
– computers, processors and similar equipment, except as specified in 1.1.3 (see IEC 950);
– transformers separate from the equipment (see IEC 742);
– equipment intended for household use (see IEC 335);
– equipment intended for use in explosive gas atmospheres (see IEC 79).
– thermal atomization detectors (flame ionization detectors) used in gas chromatography.
languageEnglish
titleUL 61010A-2-061num
titleUL Standard for Safety Electrical Equipment for Laboratory Use; Part 2: Particular Requirements for Laboratory Atomic Spectrometers with Thermal Atomization and Ionization - First Editionen
typestandard
page24
statusActive
treeUL - UL:;2002
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record