Show simple item record

Effect of shot peening on surface fatigue life of carburized and hardened AISI 9310 spur gears

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T15:26:02Z
date available2017-09-04T15:26:02Z
date copyright01/01/1982
date issued1982
identifier otherNNBBFEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/26712
description abstractSurface fatigue tests were conducted on two groups of AISI 9310 spur gears. Both groups were manufactured with standard ground tooth surfaces, with the second group subjected to an additional shot peening process on the gear tooth flanks. The gear pitch diameter was 8.89 cm (3.5 in.). Test conditions were a gear temperature of 350 K (170 F), a maximum Hertz stress of 1.71 billion N/sq m (248,000 psi), and a speed of 10,000 rpm. The shot peened gears exhibited pitting fatigue lives 1.6 times the life of standard gears without shot peening. Residual stress measurements and analysis indicate that the longer fatigue life is the result of the higher compressive stress produced by the shot peening. The life for the shot peened gear was calculated to be 1.5 times that for the plain gear by using the measured residual stress difference for the standard and shot peened gears. The measured residual stress for the shot peened gears was much higher than that for the standard gears.
languageEnglish
titleNASA-TP-2047num
titleEffect of shot peening on surface fatigue life of carburized and hardened AISI 9310 spur gearsen
typestandard
page14
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1982
contenttypefulltext
subject keywordsCOMPRESSION LOADS
subject keywordsFATIGUE LIFE
subject keywordsFATIGUE TESTS
subject keywordsGEAR TEETH
subject keywordsLUBRICANTS
subject keywordsPITTING
subject keywordsRESIDUAL STRESS
subject keywordsSHOT PEENING