Show simple item record

ASME B1.25

contributor authorASME - ASME International
date accessioned2020-07-27T20:51:38Z
date available2020-07-27T20:51:38Z
date issued2019
identifier otherEUUWHGAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/280490
description abstract(a) This Standard notes technical factors that can explain measurement differences between two parties calibrating the same gage. It is directed to the metrology involved, not acceptance rules or other quality considerations. (b) While measurement uncertainty applies to the calibration of gages to any standard, this Standard focuses on gages made to ASME standards only. The calibration of gages necessitates a thorough understanding of the standards they were made to because the standards often include required conditions for and corrections to the calibration. (c) Users of this Standard should be aware that while a number of elements for each gage type are listed, independent calibration laboratories may not include them all in their reports. Agreement should be reached with outside calibration providers as to what elements are included in their various levels of calibration
languageEnglish
titleMeasurement Uncertainty Factors in the Calibration of Screw Thread Gagesen
titleASME B1.25num
typestandard
page17
statusActive
treeASME - ASME International:;2019
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record