Show simple item record

Lessons Learned - 750 psig GN2 Supply

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T15:31:12Z
date available2017-09-04T15:31:12Z
date copyright33892
date issued1992
identifier otherOCZCQCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/32697
description abstractDescription of Driving Event:
The supply system for the 750 psig GN2 is designed such that pressure may not be removed from flodyne valves for removal/replacement, a SCAPE operation, without removing pressure which actuates other relevant components. Inadequate isolation capability of actuation pressure could result in loss of valve control, allowing valve to open when it should be closed. This could allow trapped residuals in the cross country line to drain back to the storage area, possibly resulting in a hypergol spill or fire.
languageEnglish
titleNASA-LLIS-0163num
titleLessons Learned - 750 psig GN2 Supplyen
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1992
contenttypefulltext
subject keywordsHardware
subject keywordsLogistics


Files in this item