description abstract4.1 Boron carbide is used as a control material in nuclear reactors. In order to be suitable for this purpose, the material must meet certain criteria for assay, isotopic composition, and impurity content. These methods are designed to show whether or not a given material meets the specifications for these items as described in Specifications C750 and C751. 4.1.1 An assay is performed to determine whether the material has the specified boron and carbon content. 4.1.2 Determination of the isotopic content of the boron and the free carbon content is made to establish whether the content is in compliance with the purchaser’s specifications. 4.1.3 Impurity content is determined to ensure that the maximum content limit of certain impurities (chloride, fluoride, water, metallic impurities, soluble boron) is not exceeded.
languageEnglish
titleStandard Test Methods for Chemical, Mass Spectrometric, and Spectrochemical Analysis of Nuclear-Grade Boron Carbideen
titleASTM C791-24num
typestandard
statusActive
treeASTM - ASTM International:;2024
contenttypefulltext
scope1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade boron carbide powder and pellets to determine compliance with specifications. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 The analytical procedures appear in the following order:   Sections Total Carbon by Combustion in an Inductive Furnace and     Infrared Measurement 8 – 17 Total Boron by Titrimetry and ICP-OES 18 – 28 Isotopic Composition by Mass Spectrometry 29 – 33 Pyrohydrolysis 34 – 41 Chloride by Constant-Current Coulometry 42 – 50 Chloride and Fluoride by Ion-Selective Electrode 51 – 59 Water by Constant-Voltage Coulometry and Weight Loss on     Drying 60 – 63 Metallic Impurities by DCArc-OES and wet chemical methods 64 and 65 Soluble Boron by Titrimetry and ICP-OES 66 – 80 Free Carbon by a Coulometric Method 81 – 90 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
identifier DOI10.1520/C0791-24


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record