Show simple item record

Lessons Learned - Location of Hydraulic Check Valve Prevented Leak Testing of Flex hose Using Ground Pumping Unit [GSE]

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T15:39:37Z
date available2017-09-04T15:39:37Z
date copyright05/20/2010
date issued2010
identifier otherPBMGFDAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/41762
description abstractAbstract:
The location of the check valve in the hydraulic filter module of the Ground Pumping Unit prevented ground supply pressure to be applied the supply flex hose. The location of the check valve should have been designed to provide leak testing of the supply hose using the ground pumping unit. In the future, consider removal and replacement of line replacement units (LRUs) when locating check valves in flight fluid systems.
languageEnglish
titleNASA-LLIS-3221num
titleLessons Learned - Location of Hydraulic Check Valve Prevented Leak Testing of Flex hose Using Ground Pumping Unit [GSE]en
typestandard
page1
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;2010
contenttypefulltext
subject keywordsEngineering design and project processes and standards
subject keywordsEntry Systems