Lessons Learned – VO'75 Pressure Regulator Leakage and Work-Around Procedures (~1976)

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T15:42:41Z
date available2017-09-04T15:42:41Z
date copyright07/08/1996
date issued1996
identifier otherPKBEQCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/44936
description abstractAbstract:
The pressure regulator in the Viking Orbiter Propulsion Subsystem started leaking following a pyro firing that occurred prior to the near-Mars TCM. Likely causes were corrosion or residue from propellant migration or pyro valve blowby, or particulate contamination. Recommendations included using separate regulators for the fuel and oxidizer sides, incorporating a bellows in the pyro valve to eliminate blowby, and adding a isolation valve between the regulator and propellant tank.
languageEnglish
titleNASA-LLIS-0420num
titleLessons Learned – VO'75 Pressure Regulator Leakage and Work-Around Procedures (~1976)en
typestandard
page3
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1996
contenttypefulltext
subject keywordsEnergetic Materials - Explosive/Propellant/Pyrotechnic
subject keywordsMaterial Compatibility
subject keywordsPressure Vessels
subject keywordsPropellant Feed System