ASME OM CODE CASES
Code Cases to OM CODE Code for Operation and Maintenance of Nuclear Power Plants
| contributor author | ASME - ASME International | |
| date accessioned | 2017-09-04T15:54:58Z | |
| date available | 2017-09-04T15:54:58Z | |
| date copyright | 2012.01.01 | |
| date issued | 2012 | |
| identifier other | QTUTCFAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/58320 | |
| description abstract | This Code Case establishes the requirements for preservice and inservice testing to assess the operational readiness of active motor-operated valves (MOVs) in light-water reactor (LWR) power plants. The MOVs covered are those required to perform an active function in shutting down a reactor to the safe shutdown condition, in maintaining the safe shut-down condition, or in mitigating the consequences of an accident. This Code Case establishes test methods, test intervals, parameters to be measured and evaluated, acceptance criteria, corrective actions, and records requirements. | |
| language | English | |
| title | ASME OM CODE CASES | num |
| title | Code Cases to OM CODE Code for Operation and Maintenance of Nuclear Power Plants | en |
| type | standard | |
| page | 68 | |
| status | Active | |
| tree | ASME - ASME International:;2012 | |
| contenttype | fulltext |

درباره ما