Show simple item record

Lessons Learned - 480 Volt Power Cable Connectors and Mating Tool; Emergency Cut Off Device for the 480 Volt Power Cables

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T16:00:18Z
date available2017-09-04T16:00:18Z
date copyright04/22/1992
date issued1992
identifier otherRHYCQCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/63442
description abstractDescription of Driving Event:
During routine operation of the portable purge unit (PPU), the 480 volt power cable connectors exploded and melted, causing the unit to shut down. The explosion was caused when the connectors' overheated multi-point contact band caused the solder to melt, destroying the connectors' Integrity. It is confirmed that the force of the explosion could seriously injure or kill personnel within a 50' radius.
languageEnglish
titleNASA-LLIS-0070num
titleLessons Learned - 480 Volt Power Cable Connectors and Mating Tool; Emergency Cut Off Device for the 480 Volt Power Cablesen
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1992
contenttypefulltext
subject keywordsEnergy
subject keywordsHardware
subject keywordsPackaging Handling Storage
subject keywordsParts Materials & Processes


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record