Show simple item record

Lessons Learned - APU Fuel Isolation Valve Assembly

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T16:01:23Z
date available2017-09-04T16:01:23Z
date copyright08/06/1992
date issued1992
identifier otherRKYCQCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/64604
description abstractDescription of Driving Event:
An APU hydrazine isolation valve assembly was removed and sent to the shipping section of logistics without being properly packaged for safe handling. In addition, there was no Q.A. check sheet and no decontamination tags with safety buy-off as being sniffed at zero parts per million. There was a conditional decontamination tag with the part indicating that it was from a fuel system, and conditionally decontaminated but absorbed or trapped fuel could out-gas. The OPF was called for safety and technical support to come and check out the valve; the valve tested positive for hydrazine and was immediately safed.
languageEnglish
titleNASA-LLIS-0099num
titleLessons Learned - APU Fuel Isolation Valve Assemblyen
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1992
contenttypefulltext
subject keywordsEnergetic Materials - Explosive/Propellant/Pyrotechnic
subject keywordsHardware
subject keywordsHazardous/Toxic Waste/Materials
subject keywordsPackaging Handling Storage