Lessons Learned – Relay Hangup Upon Power Removal

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T16:03:56Z
date available2017-09-04T16:03:56Z
date copyright07/12/1993
date issued1993
identifier otherRRZCQCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/67263
description abstractAbstract:
One Voyager Solid State Amplifier (SSA) failed to operate upon application of input power during spacecraft system test. Post-test analysis determined that a relay hangup had occurred following the previous application of power, and the original analysis had not considered decaying stored energy in the relay. Take all operating modes into consideration in circuit design. Design relay circuits so that the circuit can still apply energy to activate relay coils, even if the relay hangs up between contacts.
languageEnglish
titleNASA-LLIS-0282num
titleLessons Learned – Relay Hangup Upon Power Removalen
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1993
contenttypefulltext
subject keywordsEnergy
subject keywordsSpacecraft