Show simple item record

Measurement of Liquid Flow in Closed Conduits Using Transit-Time Ultrasonic Flowmeters

contributor authorASME - ASME International
date accessioned2017-09-04T15:09:36Z
date available2017-09-04T15:09:36Z
date copyright2011.06.17
date issued2011
identifier otherLONLMEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/7704
description abstractThis Standard applies to ultrasonic flowmeters that base their operation on the measurement of transit time of acoustic signals. This Standard concerns the volume flow-rate measurement of a single-phase liquid with steady flow or flow varying only slowly with time in a completely filled closed conduit.
Purpose
This Standard provides
(a) a description of the operating principles employed by the transit-time ultrasonic flowmeters
(b) a guideline to expected performance characteristics of transit-time ultrasonic flowmeters
(c) a description of calibration, verification, and diagnostic procedures
(d) a description of potential uncertainty sources and their reduction
(e) a common set of terminology, symbols, definitions, and specifications
languageEnglish
titleASME MFC-5.1num
titleMeasurement of Liquid Flow in Closed Conduits Using Transit-Time Ultrasonic Flowmetersen
typestandard
page24
statusActive
treeASME - ASME International:;2011
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record