description abstractThis specification defines requirements for [accelerometer type].
This specification format guide and test procedure standard applies to force-rebalance accelerometers (pendulous or translational proof mass), vibrating beam accelerometers (VBAs), and micromechanical accelerometers that range from lesser accuracy to high-accuracy devices (see 5.1).
All accelerometers have biases, scale factors, misalignments, nonlinearities, noise characteristics, and other parameters. Many of the specification requirements and verification test methods for these parameters; their stabilities; their temperature, magnetic, and other sensitivities; the accelerometer behavior through and across vibration, shock, and other environments; and the accelerometer lifetime and reliability are independent of the accelerometer type. Requirements and tests that are specific to a particular accelerometer type are described separately.
Only the clauses applicable to the given accelerometer type should be used.
This specification is not intended to define requirements for the pendulous integrating gyroscopic accelerometer (PIGA) or for the specific force integrating receiver (SFIR). These high-precision single degree-of-freedom (DOF) accelerometers use gyroscopic precessional torque to rebalance the specific force effect of nongravitational acceleration acting on a pendulous proof mass on the gyro float.
This specification also does not apply to devices (such as seismometers or open-loop piezoelectric accelerometers) that measure ac rather than low-pass and dc accelerations. Gravimeters having a limited dc measurement range around +1 g with input axis (IA) vertical are also not considered.
Purpose
This specification describes the design and performance requirements for [model number, part number, change letter (if any), other identification], manufactured by [name, address].
languageEnglish
titleIEEE 1293num
titleStandard Specification Format Guide and Test Procedure for Linear Single-Axis, Nongyroscopic Accelerometersen
typestandard
page256
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2008
contenttypefulltext
subject keywordsaccelerometer
subject keywordsgeophysical effects
subject keywordsinertial instrument
subject keywordsinertial sensor
subject keywordsmicromechanical accelerometer
subject keywordspendulous accelerometer
subject keywordspower spectal density
subject keywordsspecification
subject keywordstesting
subject keywordsvibrating beam accelerometer
subject keywordsvibration and shock


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record