CABLE, SPECIAL PURPOSE, ELECTRICAL (UNDERWATER USE)

contributor authorNAVY - OS - Naval Surface Warfare Center (NSWCIHEODTD)
date accessioned2017-09-04T16:19:12Z
date available2017-09-04T16:19:12Z
date copyright33171
date issued1990
identifier otherTHLVDAAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/82638
description abstractThis specification covers single and multi-conductor special purpose electrical cable for underwater use.
Cable shall be of the following types, as specified (see 6.2):
    Type DMU   Double Conductor, demolition, magnetic     Type DNU Double Conductor, demolition, nonmagnetic     Type DPU Double Conductor, Oil resistant, portable     Type MSU Multiple Conductor, steel core     Type MTU Multiple Conductor, cotton or jute core     Type SPU Single Conductor, heat and oil resistant flexible


The conductor size shall be in accordance with American Wire Gauge (AWG) size to 0000AWG; larger sizes shall be indicated by circular mil area.
Military part numbers shall be in accordance with the following example:
           M16839 - DMU 4        Where:             M is a prefix meaning military specification             16839 is the specification number             DMU is the cable type             4 is the AWG size

Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commanding Officer, Naval Ordnance Station, Standardization Branch (3730), Indian Head, MD 20640-5000, by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter.
Intended Use: All cable covered by this specification is suitable for underwater use. Primary uses for the various types are as follows:
           Type DMU                  For  Firing  explosives.   High  tensile  strength.   Magnetic                                      characteristics. Not for permanent installation.             Type DNU                  For firing explosives.  Medium tensile strength.  Nonmagnetic                                      characteristics. Not for permanent installation.             Type DPU and MSU          For degaussing range installation.             Type MTU                  For degaussing magnetometer installations.             Type SPU                  For deperming use.

languageEnglish
titleMIL-C-16839Enum
titleCABLE, SPECIAL PURPOSE, ELECTRICAL (UNDERWATER USE)en
typestandard
page15
statusActive
treeNAVY - OS - Naval Surface Warfare Center (NSWCIHEODTD):;1990
contenttypefulltext
subject keywordsConductors
subject keywordsDemolition
subject keywordsNonmagnetic
subject keywordsRubber insulation
subject keywordsSheath
subject keywordsWire rope