Manual of Petroleum Measurement Standards Chapter 2 - Tank Calibration Section 2C - Calibration of Upright Cylindrical Tanks Using the Optical-Triangulation Method - First Edition

contributor authorAPI - American Petroleum Institute
date accessioned2017-09-04T16:19:17Z
date available2017-09-04T16:19:17Z
date copyright01/01/2002 (R 2008)
date issued2008
identifier otherTHSKHCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/82733
description abstractThis part specifies a calibration procedure for application to tanks above 26 ft in diameter with cylindrical courses that are substantially vertical. It provides a method for determining the volumetric quantity contained within a tank at gauged liquid levels. The measurement required to determine the radius may be made internally (Clause 8) or externally (Clause 9). The external method is applicable only to tanks that are free of insulation.
Abnormally deformed tanks; e.g., dented or non-circular tanks are excluded from this section, API MPMS Chapter 2.
This method is suitable for tilted tanks up to 3% deviation from the vertical, provided that a correction is applied for the measured tilt as described in API MPMS Chapter 2.2A.
languageEnglish
titleAPI MPMS 2.2Cnum
titleManual of Petroleum Measurement Standards Chapter 2 - Tank Calibration Section 2C - Calibration of Upright Cylindrical Tanks Using the Optical-Triangulation Method - First Editionen
typestandard
page63
statusActive
treeAPI - American Petroleum Institute:;2008
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record