Gland Design, Elastomeric O-Ring Seals, Dynamic Radial, 1500 psi Max

contributor authorSAE - SAE International
date accessioned2017-09-04T16:46:11Z
date available2017-09-04T16:46:11Z
date copyright10/01/2001 (R 2012)
date issued2012
identifier otherWBRUAFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/109487
description abstractThis document establishes standard gland design criteria and dimensions for dynamic radial O-ring seal applications and provides recommendations for modifying these glands in special applications. There are no provisions in this document for anti-extrusion devices.
SI unit conversions for U.S. customary units have been provided for reference purposes.
The criteria set forth here are similar to but not identical with those in MIL-G-5514. This document is not intended to replace MIL-G-5514 for hydraulic applications.
PURPOSE:
The purpose of this document is to provide the aerospace industry with standardized dimensional criteria for dynamic radial elastomeric O-ring seal glands. It is intended for use in conjunction with ARP1231, "Gland Design, Elastomeric O-Ring Seals, General Considerations."
languageEnglish
titleSAE ARP1233Anum
titleGland Design, Elastomeric O-Ring Seals, Dynamic Radial, 1500 psi Maxen
typestandard
page13