Show simple item record

Guide to Mass Concrete

contributor authorACI - American Concrete Institute
date accessioned2017-09-04T16:47:22Z
date available2017-09-04T16:47:22Z
date copyright01/01/2005 (R 2012)
date issued2012
identifier otherWFADJBAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/110713
description abstractMass concrete is defined in ACI 116R as “any volume of concrete with dimensions large enough to require that measures be taken to cope with generation of heat from hydration of the cement and attendant volume change to minimize cracking.” The design of mass concrete structures is generally based on durability, economy, and thermal action, with strength often being a secondary, rather than a primary, concern. The one characteristic that distinguishes mass concrete from other concrete work is thermal behavior. Because the cement-water reaction is exothermic by nature, the temperature rise within a large concrete mass, where the heat is not quickly dissipated, can be quite high. Significant tensile stresses and strains may result from the restrained volume change associated with a decline in temperature as heat of hydration is dissipated. Measures should be taken where cracking due to thermal behavior may cause a loss of structural integrity and monolithic action, excessive seepage and shortening of the service life of the structure, or be aesthetically objectionable. Many of the principles in mass concrete practice can also be applied to general concrete work, whereby economic and other benefits may be realized.
This document contains a history of the development of mass concrete practice and a discussion of materials and concrete mixture proportioning, properties, construction methods, and equipment. This document covers traditionally placed and consolidated mass concrete, and does not cover roller-compacted concrete. Roller-compacted concrete is described in detail in ACI 207.5R.
Mass concreting practices were developed largely from concrete dam construction, where temperature-related cracking was first identified. Temperature-related cracking has also been experienced in other thick-section concrete structures, including mat foundations, pile caps, bridge piers, thick walls, and tunnel linings.
High compressive strengths are usually not required in mass concrete structures; however, thin arch dams are exceptions. Massive structures, such as gravity dams, resist loads primarily by their shape and mass, and only secondarily by their strength. Of more importance are durability and properties connected with temperature behavior and the tendency for cracking.
The effects of heat generation, restraint, and volume changes on the design and behavior of massive reinforced elements and structures are discussed in ACI 207.2R. Cooling and insulating systems for mass concrete are addressed in ACI 207.4R. Mixture proportioning for mass concrete is discussed in ACI 211.1.
languageEnglish
titleACI 207.1Rnum
titleGuide to Mass Concreteen
typestandard
page30
statusActive
treeACI - American Concrete Institute:;2012
contenttypefulltext
subject keywordsadmixture
subject keywordsaggregate
subject keywordsair entrainment
subject keywordsbatch
subject keywordscement
subject keywordscompressive strength
subject keywordscracking
subject keywordscreep
subject keywordscuring
subject keywordsdurability
subject keywordsfly ash
subject keywordsformwork
subject keywordsgrading
subject keywordsheat of hydration
subject keywordsmass concrete
subject keywordsmixing
subject keywordsmixture proportion
subject keywordsmodulus of elasticity
subject keywordsplacing
subject keywordsPoisson’s ratio
subject keywordspozzolan
subject keywordsshrinkage
subject keywordsstrain
subject keywordsstress
subject keywordstemperature rise
subject keywordsthermal expansion
subject keywordsvibration
subject keywordsvolume change


Files in this item