Code Requirements for Design and Construction of Concrete Structures for the Containment of Refrigerated Liquefied Gases and Commentary

contributor authorACI - American Concrete Institute
date accessioned2017-09-04T15:13:53Z
date available2017-09-04T15:13:53Z
date copyright01/01/2011
date issued2011
identifier otherMBRTDFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/12639
description abstractThis code provides minimum requirements for design and construction of reinforced concrete and prestressed concrete structures for the storage and containment of refrigerated liquefied gases (RLG) with service temperatures between +40 and –325°F. Notwithstanding, the principals listed herein are applicable to concrete foundations of double-steel tanks subject to the approval of the owner.
Container design shall include the design of the container wall, its foundation (footing and floor slab), the concrete portions of its roof, and the bund wall, whenever applicable.
languageEnglish
titleACI 376num
titleCode Requirements for Design and Construction of Concrete Structures for the Containment of Refrigerated Liquefied Gases and Commentaryen
typestandard
page153
statusActive
treeACI - American Concrete Institute:;2011
contenttypefulltext