Lessons Learned - Fluidized Bed Furnace

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T17:36:11Z
date available2017-09-04T17:36:11Z
date copyright06/14/1993
date issued1993
identifier otherDJZCQCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/159088
description abstractDescription of Driving Event:
The furnace involved was a procedyne high temperature fluidbed furnace with an 1850 degrees F maximum operating temperature. The furnace medium consisted of 1000 lbs of an alumina sand and was set to idle at 1200 F overnight. During the run fluidized media was found to be spewing out of the furnace and running down a wall in the furnace room. During the following investigation the alumina sand showed signs of sintering that suggests overheating conditions in the range of 2000 to 2200 F.
Cause of the overheating was found to be the main electrical contactor that had welded shut on 2 of the 3 legs allowing an uninterrupted supply of power to the furnace heater. Further investigation determined that a contributing factor to the mishap was the condition of the retort wall that contained a brittle fracture appearance and evidence of a stress failure rather than a thermal failure at meltdown.
The retort failed as a result of the increased thermal stress, due to the continued power supply from the stuck electrical contact, and the inherent mechanical defects in the retort wall that was not able to withstand the 2200 F temperature.
languageEnglish
titleNASA-LLIS-0211num
titleLessons Learned - Fluidized Bed Furnaceen
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1993
contenttypefulltext
subject keywordsHardware
subject keywordsIndustrial Operations


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record