Show simple item record

Lessons Learned - Portable Purge Unit (PPU) Exceeds Recommended Noise Levels

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T17:45:46Z
date available2017-09-04T17:45:46Z
date copyright05/09/1992
date issued1992
identifier otherEJYCQCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/168921
description abstractDescription of Driving Event:
The portable purge unit when operating, exceeds the recommended 85 DBA. Reference is made to noise hazard survey accomplished by BOC industrial hygiene. The noise level closer than a perimeter of 30 feet exceeds the allowable 85.0 DBA as established by the NASA Hearing Conservation Program. The DBA level near the unit ranges from 91.0 DBA to 99.6 DBA.
languageEnglish
titleNASA-LLIS-0083num
titleLessons Learned - Portable Purge Unit (PPU) Exceeds Recommended Noise Levelsen
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1992
contenttypefulltext
subject keywordsHardware
subject keywordsIndustrial Operations
subject keywordsPersonal Protective Equipment