ACI - American Concrete Institute: Recent submissions
Now showing items 601-620 of 636
-
ACI 336.3R
Abstract: This report deals with design and construction of drilled pier foundations which are constructed by digging, drilling or otherwise excavating a hole in the earth which is subsequently filled with plain or reinforced concrete. ...Subject(s) : axial loads , bearing capacity , bending , bending moments , caps (supports) , concrete construction , deflection , excavation , foundations , lateral pressure , linings , loads (forces) , moments , observation , piers , placing , quality control , reinforced concrete , slurry displacement method , soil mechanics , structural design , tolerances (mechanics) , tremie concrete , -
ACI 440.1R
Abstract: This document provides recommendations for the design and construction of FRP-reinforced concrete structures. The document only addresses nonprestressed FRP reinforcement (concrete structures prestressed with FRP tendons ...Subject(s) : carbon fibers , development length , fiber-reinforced polymers , flexure , glass fibers , moment , ramid fibers , reinforcement , shear , slab , strength , -
ACI 546.3R
Abstract: This guide discusses material selection for several types of repairs and materials used in their repair:
a) Concrete replacements, categorized on the basis of the depth and orientation of repair;
b) Overlays, ... -
ACI 548.10M
Abstract: This Specification covers materials and procedures for polymer overlays for new construction and for repair and rehabilitation of bridge and parking garage decks. Methyl methacrylate slurry (MMS) polymer overlay incorporates ...Subject(s) : aggregate , bridge decks , methyl methacrylate , mortar , overlays , parking garage decks , polymer , premixed , resin , slurry , -
ACI ITG-4.1
Abstract: General—This specification covers normalweight, high-strength concrete in structures that must be designed for moderate to high seismic applications. More specifically, this specification applies to structures: ... -
ACI 376
Abstract: This code provides minimum requirements for design and construction of reinforced concrete and prestressed concrete structures for the storage and containment of refrigerated liquefied gases (RLG) with service temperatures ... -
ACI 212.3R
Abstract: Introduction
An admixture is defined as "a material other than water, aggregates, hydraulic cement, and fiber reinforcement used as an ingredient of concrete or mortar, and added to the batch immediately ...Subject(s) : accelerating , admixture , admixture system , air-entraining , alkali-aggregate reaction , flowing concrete , high-range water-reducing admixture , permeability-reducing admixtures , self-consolidating concrete , shrinkage-reducing , water-reducing and set-retarding , -
ACI 546.3R
Abstract: This guide covers material selection for the following types of repair:
1. Concrete replacements, categorized on the basis of the depth and orientation of the repair;
2. Overlays categorized on the basis of their ...Subject(s) : cementitious , concrete , epoxy , polymer , polyurethane , repair , silica fume , test methods , -
ACI 330.1
Abstract: This specification covers requirements for the construction of unreinforced concrete parking lots and site paving on grade, including attached and integral curbs. Site paving includes entrance and exit lanes as well as ... -
ACI 214.4R
Abstract: This guide summarizes current practices for obtaining cores and interpreting core compressive strength test results in light of past and current research findings. Many of these findings are based on older references as ...Subject(s) : compressive strength , core , hardened concrete , sampling , test , -
ACI 332.1R
Abstract: This code provides minimum requirements for design and construction of residential concrete elements when legally adopted as part of a general building code, of which this code forms a part. In areas without a legally ... -
ACI 346
Abstract: This specification covers construction of earthsupported cast-in-place concrete pipe (CIPCP). This specification covers construction of CIPCP with a diameter up to 120 in.
CIPCP shall conform to ACI 301, Section 1 for ...Subject(s) : cast-in-place concrete pipe (CIPCP) , circumferential cracking , concrete pipe , longitudinal cracking , no-joint pipe , -
ACI 349
Abstract: This Code provides minimum requirements for design and construction of nuclear safety-related concrete structures and structural members for nuclear facilities. Safety-related structures and structural members subject to ... -
ACI 364.5T
Abstract: Summary
Surface repairs must be dimensionally and mechanically compatible with the existing concrete substrate to minimize cracking and ensure that the repair and existing structure act monolithically. ...Subject(s) : compatibility , cracking , creep , elastic modulus , load-carrying , repair , strain , stress , tension , -
ACI 544.2R
Abstract: INTRODUCTION
This report applies to conventionally mixed and placed fiber reinforced concrete (FRC) or fiber reinforced shotcrete (FRS) using steel, glass, polymeric, and natural fibers. It does not ...Subject(s) : abrasion tests , cavitation , compression tests , cracking (fracturing) , creep properties , energy absorption , erosion , fatigue (materials) , fiber reinforced concretes , flexural strength , freeze-thaw durability , impact tests , modulus of elasticity , shrinkage , splitting tensile strength , tests , toughness , workability , -
ACI 221.1R
Abstract: This report is intended to provide information on ASR and ACR. Accordingly, chapters in this report provide an overview of the nature of both ASR and ACR reactions, the means of avoiding the deleterious effects of each ...Subject(s) : aggregates , alkali-aggregate reactivity , alkali-carbonate reactivity , alkali-silica reactivity , concrete , concrete distress , concrete durability , -
ACI 350.2R ERTA
Abstract: This report is intended for use in the structural design and construction of hazardous material containment systems. Hazardous material containment structures require secondary containment and, sometimes, leak-detection ...Subject(s) : construction joint , joint , joint sealant , precast concrete , prestress , water-cementitious material ratio , waterstop , -
ACI 307 ERTA
Abstract: This standard covers the design and construction of circular cast-in-place or precast reinforced concrete chimney shells. If other shapes are used, their design shall be substantiated in accordance with the principles used ...Subject(s) : chimneys , compressive strength , concrete construction , earthquake-resistant structures , formwork (construction) , foundations , high temperature , linings , loads (forces) , moments , openings , precast concrete , quality control , reinforced concrete , reinforcing steels , specifications , static loads , strength , structural analysis , structural design , temperature , thermal gradient , wind pressure ,

درباره ما