AHRI 750
Thermostatic Refrigerant Expansion Valves
Year: 2007
Abstract: This standard applies to Thermostatic Refrigerant Expansion Valves for use with refrigerants listed in 2.1.1 at evaporator temperatures between 50°F [10°C] and -40°F [-40°C].
Refrigerants. The refrigerants included in this standard are: R-12, R-22, R-134a, R-404A, R-407C, R-410A, R- 502 and R-507A.
Purpose. The purpose of this standard is to establish for Thermostatic Refrigerant Expansion Valves: definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions.
Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users.
Review and Amendment. This standard is subject to review and amendment as technology advances.
Refrigerants. The refrigerants included in this standard are: R-12, R-22, R-134a, R-404A, R-407C, R-410A, R- 502 and R-507A.
Purpose. The purpose of this standard is to establish for Thermostatic Refrigerant Expansion Valves: definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions.
Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users.
Review and Amendment. This standard is subject to review and amendment as technology advances.
Show full item record
contributor author | AHRI - Air-Conditioning, Heating and Refrigeration Institute | |
date accessioned | 2017-09-04T17:55:17Z | |
date available | 2017-09-04T17:55:17Z | |
date copyright | 01/01/2007 | |
date issued | 2007 | |
identifier other | FJJDBCAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std/handle/yse/178389 | |
description abstract | This standard applies to Thermostatic Refrigerant Expansion Valves for use with refrigerants listed in 2.1.1 at evaporator temperatures between 50°F [10°C] and -40°F [-40°C]. Refrigerants. The refrigerants included in this standard are: R-12, R-22, R-134a, R-404A, R-407C, R-410A, R- 502 and R-507A. Purpose. The purpose of this standard is to establish for Thermostatic Refrigerant Expansion Valves: definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. Review and Amendment. This standard is subject to review and amendment as technology advances. | |
language | English | |
title | AHRI 750 | num |
title | Thermostatic Refrigerant Expansion Valves | en |
type | standard | |
page | 11 | |
status | Active | |
tree | AHRI - Air-Conditioning, Heating and Refrigeration Institute:;2007 | |
contenttype | fulltext |