IMPREGNATION OF CASTINGS

contributor authorSAE - SAE International
date accessioned2017-09-04T15:31:51Z
date available2017-09-04T15:31:51Z
date copyright03/01/1942
date issued1942
identifier otherAXCBBFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/33379
description abstractAPPLICATION:
All parts shall be pressure tested with water or air. Those which leak equivalent to more than 25 drops of water per minute on a local area shall be rejected. Those which leak equivalent to a rate of 5 to 25 drops of water per minute may be impregnated. Those which leak equivalent to less than 5 drops of water per minute are acceptable without impregnation unless the leakage would be into the induction system, or through an external surface, or through the walls of the coolant jacket, in which case they must be impregnated. The purchaser's Inspection Department may vary this requirement after giving consideration to the use of the part, the location of the leaks, and other pertinent factors.
languageEnglish
titleSAE AMS2560Anum
titleIMPREGNATION OF CASTINGSen
typestandard
page3
statusCancelled
treeSAE - SAE International:;1942
contenttypefulltext