Standard Practice for Computed Tomographic (CT) Examination of Castings
ASTM E1814-25
| contributor author | ASTM - ASTM International | |
| date accessioned | 2025-09-30T19:29:54Z | |
| date available | 2025-09-30T19:29:54Z | |
| date copyright | 2025 | |
| date issued | 2025 | |
| identifier other | e1814-25.pdf | |
| identifier uri | http://yse.yabesh.ir/std/handle/yse/343914 | |
| description abstract | 4.1 CT may be performed on an object when it is in the as-cast, intermediate, final machined condition, or as a flaw or failure detection tool. A CT examination can be used as a design tool to improve wax forms and moldings, establish process parameters, randomly check process control, perform final quality control (QC) examination for the acceptance or rejection of parts, and analyze failures and extend component lifetimes. 4.2 The most common applications of CT for castings are for the following: locating and characterizing discontinuities, such as porosity, inclusions, cracks, and shrink; measuring as-cast part dimensions for comparison with design dimensions; wall thickness quantification; and extracting dimensional measurements for reverse engineering. 4.3 The quality to which a CT image reproduces an object or a feature within an object is dictated largely by the competing influences of the specific geometry, spatial resolution, contrast sensitivity, and material of the object itself, and artifacts of the imaging system. Operating parameters strike an overall balance between image quality, examination time, and cost. 4.4 Artifacts are often the limiting factor in CT image quality. (See Guide E1441 for an in-depth discussion of artifacts.) Artifacts are reproducible features in an image that are not related to actual features in the object. Artifacts can be considered correlated noise because they form repeatable fixed patterns under given conditions yet carry no object information. For castings, it is imperative to recognize what is and is not an artifact since an artifact can obscure or masquerade as a discontinuity or affect dimensional measurements. 4.5 When processing castings in accordance to this document, Practice E3375 may be used to help in the development of an approved process. | |
| language | English | |
| title | Standard Practice for Computed Tomographic (CT) Examination of Castings | en | 
| title | ASTM E1814-25 | num | 
| type | standard | |
| status | Active | |
| tree | ASTM - ASTM International:;2025 | |
| contenttype | fulltext | |
| scope | 1.1 This practice covers a uniform procedure for the examination of castings by the computed tomography (CT) technique including both cone and fan beam. The requirements expressed in this practice are intended to control the quality of the nondestructive examination by CT and are not intended for controlling the acceptability or quality of the castings. This practice implicitly suggests the use of penetrating radiation, specifically X rays and gamma rays. 1.2 This practice provides a uniform procedure for a CT examination of castings for one or more of the following purposes: 1.2.1 Examining for discontinuities, such as porosity, inclusions, cracks, and shrink; 1.2.2 Performing measurements and determining conformance; and 1.2.3 Determining reverse engineering data, that is, creating computer-aided design (CAD) data files. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. | |
| identifier DOI | 10.1520/E1814-25 | 