Show simple item record

Automatic Sprinkler Systems Handbook - TWELFTH EDITION

contributor authorNFPA - (NFPA) - National Fluid Power Association
date accessioned2017-09-04T15:42:25Z
date available2017-09-04T15:42:25Z
date copyright2013.01.01
date issued2013
identifier otherPJJBBFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/44699
description abstractThis standard provides a range of sprinkler system approaches, design development alternatives, and component options that are all acceptable. Building owners and their designated representatives are advised to carefully evaluate proposed selections for appropriateness and preference.
This standard shall provide the minimum requirements for the design and installation of automatic fire sprinkler systems and exposure protection sprinkler systems covered within this standard.
This standard shall not provide requirements for the design or installation of water mist fire protection systems, which are not considered fire sprinkler systems and are addressed by NFPA 750.
This standard is written with the assumption that the sprinkler system shall be designed to protect against a single fire originating within the building.
This standard also provides guidance for the installation of systems for exterior protection and specific hazards. Where these systems are installed, they are also designed for protection of a fire from a single ignition source.
Purpose
Since its inception, this document has been developed on the basis of standardized materials, devices, and design practices. However, Section 1.2 and other subsections such as 6.3.7.8 and 8.4.8 allow the use of materials and devices not specifically designated by this standard, provided such use is within parameters established by a listing organization. In using such materials or devices, it is important that all conditions, requirements, and limitations of the listing be fully understood and accepted and that the installation be in complete accord with such listing requirements.
The purpose of this standard shall be to provide a reasonable degree of protection for life and property from fire through standardization of design, installation, and testing requirements for sprinkler systems, including private fire service mains, based on sound engineering principles, test data, and field experience.
languageEnglish
titleNFPA 13Hnum
titleAutomatic Sprinkler Systems Handbook - TWELFTH EDITIONen
typestandard
page1247
statusActive
treeNFPA - (NFPA) - National Fluid Power Association:;2013
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record