Now showing items 1-5 of 5

      • MIL-STD-188 -125-1 

        Type: standard
        Source: DOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo):;1998
        Organization : DOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo)
        Abstract: This standard establishes minimum requirements and design objectives for high-altitude electromagnetic pulse (HEMP) hardening of fixed1 ground-based facilities that perform critical, time-urgent command, ...
        Subject(s) : Continuous wave immersion , Electric surge arrester , Electromagnetic barrier , Facility HEMP shield , Hardening , Hardness verification , High-altitude electromagnetic pulse , Low-risk HEMP protection , Mission-critical systems , Nuclear survivability , POE , POE protective device , Pulsed current injection , Shielding effectiveness , Special protective measures , Survivability/vulnerability , Transient suppression/attenuation device , Waveguide below cutoff ,
      • MIL-STD-188 -125-2 VALID NOTICE 1 

        Type: standard
        Source: DOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo):;2005
        Organization : DOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo)
      • MIL-STD-188-125-1 VALID NOTICE 1 

        Type: standard
        Source: DOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo):;2005
        Organization : DOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo)
      • MIL-STD-188-125-2 

        Type: standard
        Source: DOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo):;1999
        Organization : DOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo)
        Abstract: This standard prescribes minimum performance requirements for low-risk protection from mission-aborting damage or upset due to HEMP threat environments defined in MIL-STD-2169. The standard also addresses minimum testing ...
        Subject(s) : Continuous wave immersion , Electric surge arrester , Electromagnetic barrier , Hardening , Hardness verification , High-altitude electromagnetic pulse , Low-risk HEMP protection , Mission-critical equipment , Nuclear survivability , POE protective device , Point-of-entry , Pulsed current injection , Shielding effectiveness , Special protective measures , Subsystem HEMP shield , Survivability/vulnerability , Transient suppression/attenuation device , Waveguide below cutoff ,
      • MIL-STD-2169B NOTICE 1 

        Type: standard
        Source: DOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo):;2012
        Organization : DOD - DS - Defense Threat Reduction Agency (DTRA), (DepSo)