French -- Appareillage à basse tension - Partie 9-1: Systèmes actifs de limitation des défauts d'arc - Dispositifs d'extinction d'arc - Edition 1.0|English -- Low-voltage switchgear and controlgear -Part 9-1: Active arc-fault mitigation systems - Arc quenching devices - Edition 1.0
IEC 60947-9-1
Organization:
IEC - International Electrotechnical Commission
Year: 2019
Abstract: Scope: This part of IEC 60947 covers low-voltage arc quenching devices, hereinafter referred to as AQDs, which are intended to eliminate arc-faults in low-voltage assemblies (typically lowvoltage switchgear and controlgear assemblies in accordance with the IEC 61439 series), by creating a lower impedance current path, to cause the arcing current to transfer to the new current path. This new current path is maintained until a short-circuit protection device (SCPD) interrupts the short-circuit current. AQDs are installed in low-voltage assemblies, connected to the main circuit, preferably as close as possible to all primary power sources. Their rated voltage does not exceed 1 000 V AC or 1 500 V DC. This document does not cover: • sensors intended to detect arc-faults; • devices intended to trigger the functioning of the arc quenching device; • devices intended to interrupt arc-fault current; • special requirements for AQDs for use in explosive atmospheres (e.g. ATEX).
Collections
:
-
Statistics
French -- Appareillage à basse tension - Partie 9-1: Systèmes actifs de limitation des défauts d'arc - Dispositifs d'extinction d'arc - Edition 1.0|English -- Low-voltage switchgear and controlgear -Part 9-1: Active arc-fault mitigation systems - Arc quenching devices - Edition 1.0
Show full item record
| contributor author | IEC - International Electrotechnical Commission | |
| date accessioned | 2020-09-15T22:28:12Z | |
| date available | 2020-09-15T22:28:12Z | |
| date copyright | 2019.01.01 | |
| date issued | 2019 | |
| identifier other | QMBWGGAAAAAAAAAA.pdf | |
| identifier other | QMBWGGAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std;jse/handle/yse/288977 | |
| description abstract | Scope: This part of IEC 60947 covers low-voltage arc quenching devices, hereinafter referred to as AQDs, which are intended to eliminate arc-faults in low-voltage assemblies (typically lowvoltage switchgear and controlgear assemblies in accordance with the IEC 61439 series), by creating a lower impedance current path, to cause the arcing current to transfer to the new current path. This new current path is maintained until a short-circuit protection device (SCPD) interrupts the short-circuit current. AQDs are installed in low-voltage assemblies, connected to the main circuit, preferably as close as possible to all primary power sources. Their rated voltage does not exceed 1 000 V AC or 1 500 V DC. This document does not cover: • sensors intended to detect arc-faults; • devices intended to trigger the functioning of the arc quenching device; • devices intended to interrupt arc-fault current; • special requirements for AQDs for use in explosive atmospheres (e.g. ATEX). | |
| language | English, French | |
| title | French -- Appareillage à basse tension - Partie 9-1: Systèmes actifs de limitation des défauts d'arc - Dispositifs d'extinction d'arc - Edition 1.0|English -- Low-voltage switchgear and controlgear -Part 9-1: Active arc-fault mitigation systems - Arc quenching devices - Edition 1.0 | en |
| title | IEC 60947-9-1 | num |
| type | standard | |
| page | 42 | |
| status | Active | |
| tree | IEC - International Electrotechnical Commission:;2019 | |
| contenttype | fulltext |