• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • IEC - International Electrotechnical Commission
  • View Item
  •   YSE
  • Industrial Standards
  • IEC - International Electrotechnical Commission
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

French -- Lampes à LED autoballastées pour l'éclairage général avec des tensions d'alimentation > 50 V - Exigences de performances - Edition 1.2; Consolidated Reprint|English -- Self-ballasted LED lamps for general lighting services with supply voltages > 50 V - Performance requirements - Edition 1.2; Consolidated Reprint

IEC 62612

Organization:
IEC - International Electrotechnical Commission
Year: 2018

Abstract: Scope: This International Standard specifies the performance requirements, together with the test methods and conditions, required to show compliance of LED lamps with integral means for stable operation, intended for domestic and similar general lighting purposes, having: • a rated power up to 60 W; • a rated voltage of > 50 V a.c. up to 250 V a.c.; • a lamp cap as listed in IEC 62560. These performance requirements are additional to the safety requirements in IEC 62560. The only feature provided by this standard, when applied for replacement purposes, is information on maximum lamp outlines. The requirements of this standard relate to type testing. This standard covers LED lamps that intentionally produce white light, based on inorganic LEDs. Recommendations for whole product testing or batch testing are under consideration. The life time of LED lamps is in most cases much longer than the practical test times. Consequently, verification of manufacturer’s life time claims cannot be made in a sufficiently confident way, because projecting test data further in time is not standardised. For that reason the acceptance or rejection of a manufacturer\'s life time claim, past an operational time as stated in 7.1, is out of the scope of this standard. Instead of life time validation, this standard has opted for lumen maintenance codes at a defined finite test time. Therefore, the code number does not imply a prediction of achievable life time. The categories, represented by the code, are lumen-depreciation character categories showing behaviour in agreement with manufacturer’s information, provided before the test is started. In order to validate a life time claim, several methods of test data extrapolation exist. A general method of projecting measurement data beyond limited test time is under consideration. The pass/fail criterion of the life time test as defined in this standard is different from the life time metrics claimed by manufacturers. For explanation of recommended life time metrics, see Annex E. NOTE When lamps are operated in a luminaire the claimed performance data can deviate from the values established via this standard due to e.g. luminaire components that impact the performance of the lamp. It can be expected that self-ballasted LED lamps, which comply with this standard will start and operate satisfactorily at voltages between 92 % and 106 % of rated supply voltage and at an ambient air temperature between –20 °C and 40 °C and in a luminaire complying with IEC 60598-1. If a supplier claims suitability for operation at different conditions (for instance, at higher voltage, temperature or humidity) then: a) Lamps shall be tested under claimed different conditions; and b) Lamps shall start and operate satisfactorily under claimed different conditions; and c) Lamps shall meet the performance claims under the claimed different conditions, which may differ from the general conditions for measurement specified in A.1.
URI: http://yse.yabesh.ir/std;jsein/handle/yse/288880
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (2.724Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    French -- Lampes à LED autoballastées pour l'éclairage général avec des tensions d'alimentation > 50 V - Exigences de performances - Edition 1.2; Consolidated Reprint|English -- Self-ballasted LED lamps for general lighting services with supply voltages > 50 V - Performance requirements - Edition 1.2; Consolidated Reprint

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2020-09-15T22:27:46Z
date available2020-09-15T22:27:46Z
date copyright2018.08.01
date issued2018
identifier otherJEPEGGAAAAAAAAAA.pdf
identifier otherJEPEGGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsein/handle/yse/288880
description abstractScope: This International Standard specifies the performance requirements, together with the test methods and conditions, required to show compliance of LED lamps with integral means for stable operation, intended for domestic and similar general lighting purposes, having: • a rated power up to 60 W; • a rated voltage of > 50 V a.c. up to 250 V a.c.; • a lamp cap as listed in IEC 62560. These performance requirements are additional to the safety requirements in IEC 62560. The only feature provided by this standard, when applied for replacement purposes, is information on maximum lamp outlines. The requirements of this standard relate to type testing. This standard covers LED lamps that intentionally produce white light, based on inorganic LEDs. Recommendations for whole product testing or batch testing are under consideration. The life time of LED lamps is in most cases much longer than the practical test times. Consequently, verification of manufacturer’s life time claims cannot be made in a sufficiently confident way, because projecting test data further in time is not standardised. For that reason the acceptance or rejection of a manufacturer\'s life time claim, past an operational time as stated in 7.1, is out of the scope of this standard. Instead of life time validation, this standard has opted for lumen maintenance codes at a defined finite test time. Therefore, the code number does not imply a prediction of achievable life time. The categories, represented by the code, are lumen-depreciation character categories showing behaviour in agreement with manufacturer’s information, provided before the test is started. In order to validate a life time claim, several methods of test data extrapolation exist. A general method of projecting measurement data beyond limited test time is under consideration. The pass/fail criterion of the life time test as defined in this standard is different from the life time metrics claimed by manufacturers. For explanation of recommended life time metrics, see Annex E. NOTE When lamps are operated in a luminaire the claimed performance data can deviate from the values established via this standard due to e.g. luminaire components that impact the performance of the lamp. It can be expected that self-ballasted LED lamps, which comply with this standard will start and operate satisfactorily at voltages between 92 % and 106 % of rated supply voltage and at an ambient air temperature between –20 °C and 40 °C and in a luminaire complying with IEC 60598-1. If a supplier claims suitability for operation at different conditions (for instance, at higher voltage, temperature or humidity) then: a) Lamps shall be tested under claimed different conditions; and b) Lamps shall start and operate satisfactorily under claimed different conditions; and c) Lamps shall meet the performance claims under the claimed different conditions, which may differ from the general conditions for measurement specified in A.1.
languageEnglish, French
titleFrench -- Lampes à LED autoballastées pour l'éclairage général avec des tensions d'alimentation > 50 V - Exigences de performances - Edition 1.2; Consolidated Reprint|English -- Self-ballasted LED lamps for general lighting services with supply voltages > 50 V - Performance requirements - Edition 1.2; Consolidated Reprinten
titleIEC 62612num
typestandard
page192
statusActive
treeIEC - International Electrotechnical Commission:;2018
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian