Archive

French -- Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques – Partie 1-1: Appareils de mesure des perturbations radioélectriques et de l’immunité aux perturbations radioélectriques – Appareils de mesure - Edition 5.0|English -- Specification for radio disturbance and immunity measuring apparatus and methods – Part 1-1: Radio disturbance and immunity measuring apparatus – Measuring apparatus - Edition 5.0

IEC CISPR 16-1-1

Organization:
IEC - International Electrotechnical Commission
Year: 2019

Abstract: Scope: This part of CISPR 16 specifies the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz. In addition, requirements are provided for specialized equipment for discontinuous disturbance measurements. NOTE In accordance with IEC Guide 107, CISPR 16-1-1 is a basic electromagnetic compatibility (EMC) standard for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of a basic EMC standard. CISPR and its subcommittee are prepared to co-operate with product committees in the evaluation of the value of particular EMC tests for specific products. The specifications in this document apply to electromagnetic interference (EMI) receivers and spectrum analyzers. The term “measuring receiver” used in this document refers to both EMI receivers and spectrum analyzers (see also 3.7). The calibration requirements for measuring receivers are detailed in Annex J. Further guidance on the use of spectrum analyzers can be found in Annex B of any one of the following documents: CISPR 16-2-1:2014, CISPR 16-2-2:2010, or CISPR 16-2-3: 2016.
URI: http://yse.yabesh.ir/std;jsein/handle/yse/288935
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (4.266Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    French -- Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques – Partie 1-1: Appareils de mesure des perturbations radioélectriques et de l’immunité aux perturbations radioélectriques – Appareils de mesure - Edition 5.0|English -- Specification for radio disturbance and immunity measuring apparatus and methods – Part 1-1: Radio disturbance and immunity measuring apparatus – Measuring apparatus - Edition 5.0

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2020-09-15T22:28:00Z
date available2020-09-15T22:28:00Z
date copyright2019.05.01
date issued2019
identifier otherMVGYHGAAAAAAAAAA.pdf
identifier otherMVGYHGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsein/handle/yse/288935
description abstractScope: This part of CISPR 16 specifies the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz. In addition, requirements are provided for specialized equipment for discontinuous disturbance measurements. NOTE In accordance with IEC Guide 107, CISPR 16-1-1 is a basic electromagnetic compatibility (EMC) standard for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of a basic EMC standard. CISPR and its subcommittee are prepared to co-operate with product committees in the evaluation of the value of particular EMC tests for specific products. The specifications in this document apply to electromagnetic interference (EMI) receivers and spectrum analyzers. The term “measuring receiver” used in this document refers to both EMI receivers and spectrum analyzers (see also 3.7). The calibration requirements for measuring receivers are detailed in Annex J. Further guidance on the use of spectrum analyzers can be found in Annex B of any one of the following documents: CISPR 16-2-1:2014, CISPR 16-2-2:2010, or CISPR 16-2-3: 2016.
languageEnglish, French
titleFrench -- Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques – Partie 1-1: Appareils de mesure des perturbations radioélectriques et de l’immunité aux perturbations radioélectriques – Appareils de mesure - Edition 5.0|English -- Specification for radio disturbance and immunity measuring apparatus and methods – Part 1-1: Radio disturbance and immunity measuring apparatus – Measuring apparatus - Edition 5.0en
titleIEC CISPR 16-1-1num
typestandard
page200
statusActive
treeIEC - International Electrotechnical Commission:;2019
contenttypefulltext