Archive

French -- Atmosphères des lieux de travail – Partie 1: Détecteurs de gaz – Exigences d'aptitude à la fonction des détecteurs de gaz toxiques - Edition 1.0|English -- Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases - Edition 1.0

IEC 62990-1

Organization:
IEC - International Electrotechnical Commission
Year: 2019

Abstract: Scope: This part of ISO/IEC 62990 specifies general requirements for design, function and performance, and describes the test methods that apply to portable, transportable, and fixed equipment for the detection and concentration measurement of toxic gases and vapours in workplace atmospheres and other industrial and commercial applications. This document is applicable to continuously sensing equipment whose primary purpose is to provide an indication, alarm and/or other output function the purpose of which is to indicate the presence of a toxic gas or vapour in the atmosphere and in some cases to initiate automatic or manual protective action(s). It is applicable to equipment in which the sensor generates an electrical signal when gas is present. This document applies to two types of equipment: • Type HM (Health Monitoring) ‘occupational exposure’ equipment: For occupational exposure measurement, the performance requirements are focused on uncertainty of measurement of gas concentrations in the region of Occupational Exposure Limit Values (OELV). The upper limit of measurement will be defined by the manufacturer in accordance with 4.2.1. • Type SM (Safety Monitoring) ‘general gas detection’ equipment: For general gas detection applications (e.g. safety warning, leak detection), the performance requirements are focused on alarm signalling. The upper limit of measurement will be defined by the manufacturer according to the intended use of the equipment. In general, the requirements for accuracy will be higher for Type HM equipment than for Type SM equipment. The same equipment may meet the requirements of both Type HM and Type SM. For equipment used for sensing the presence of multiple gases this document applies only to the detection of toxic gas or vapour. This document is not applicable to equipment: – with samplers and concentrators such as sorbents or paper tape having an irreversible indication; – used for the measurement of gases and vapours related to the risk of explosion; – used for the measurement of oxygen; – used only in laboratories for analysis or measurement; – used only for process measurement purposes; – used in the domestic environment; – used in environmental air pollution monitoring; – used for open-path (line of sight) area gas measurement; – used for ventilation control in car parks or tunnels  
URI: http://yse.yabesh.ir/std;jsein/handle/yse/288953
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (1.989Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    French -- Atmosphères des lieux de travail – Partie 1: Détecteurs de gaz – Exigences d'aptitude à la fonction des détecteurs de gaz toxiques - Edition 1.0|English -- Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases - Edition 1.0

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2020-09-15T22:28:06Z
date available2020-09-15T22:28:06Z
date copyright2019.06.01
date issued2019
identifier otherOJHEIGAAAAAAAAAA.pdf
identifier otherOJHEIGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsein/handle/yse/288953
description abstractScope: This part of ISO/IEC 62990 specifies general requirements for design, function and performance, and describes the test methods that apply to portable, transportable, and fixed equipment for the detection and concentration measurement of toxic gases and vapours in workplace atmospheres and other industrial and commercial applications. This document is applicable to continuously sensing equipment whose primary purpose is to provide an indication, alarm and/or other output function the purpose of which is to indicate the presence of a toxic gas or vapour in the atmosphere and in some cases to initiate automatic or manual protective action(s). It is applicable to equipment in which the sensor generates an electrical signal when gas is present. This document applies to two types of equipment: • Type HM (Health Monitoring) ‘occupational exposure’ equipment: For occupational exposure measurement, the performance requirements are focused on uncertainty of measurement of gas concentrations in the region of Occupational Exposure Limit Values (OELV). The upper limit of measurement will be defined by the manufacturer in accordance with 4.2.1. • Type SM (Safety Monitoring) ‘general gas detection’ equipment: For general gas detection applications (e.g. safety warning, leak detection), the performance requirements are focused on alarm signalling. The upper limit of measurement will be defined by the manufacturer according to the intended use of the equipment. In general, the requirements for accuracy will be higher for Type HM equipment than for Type SM equipment. The same equipment may meet the requirements of both Type HM and Type SM. For equipment used for sensing the presence of multiple gases this document applies only to the detection of toxic gas or vapour. This document is not applicable to equipment: – with samplers and concentrators such as sorbents or paper tape having an irreversible indication; – used for the measurement of gases and vapours related to the risk of explosion; – used for the measurement of oxygen; – used only in laboratories for analysis or measurement; – used only for process measurement purposes; – used in the domestic environment; – used in environmental air pollution monitoring; – used for open-path (line of sight) area gas measurement; – used for ventilation control in car parks or tunnels  
languageEnglish, French
titleFrench -- Atmosphères des lieux de travail – Partie 1: Détecteurs de gaz – Exigences d'aptitude à la fonction des détecteurs de gaz toxiques - Edition 1.0|English -- Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases - Edition 1.0en
titleIEC 62990-1num
typestandard
page128
statusActive
treeIEC - International Electrotechnical Commission:;2019
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian