English -- High-voltage switchgear and controlgear – Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV - Edition 3.0
IEC 62271-107 (REDLINE + STANDARD)
Organization:
IEC - International Electrotechnical Commission
Year: 2019
Abstract: Scope: This part of IEC 62271 applies to three-pole-operated fused circuit-switchers designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. They can be designed either as stand-alone devices, or be embedded in a switchgear and controlgear assembly. They are intended to be used for circuits or applications requiring only a normal mechanical and electrical endurance capability. Such applications cover protection of HV/LV transformers for instance, but exclude distribution lines or cables, as well as motor circuits and capacitor bank circuits. Short-circuit conditions with low currents, up to the fused circuit-switcher rated take-over current, are dealt with by supplementary devices (strikers, relays, etc.), properly arranged, tripping the circuit-switcher. Current-limiting fuses are incorporated in order to ensure that the short-circuit breaking capacity of the device is above that of the circuit-switcher alone. NOTE 1 In this document, the term "fuse" is used to designate either the fuse or the fuse-link where the general meaning of the text does not result in ambiguity. NOTE 2 Other circuit-switchers exist; see reference [4]. Devices that require a dependent manual operation are not covered by this document.
Collections
:
-
Statistics
English -- High-voltage switchgear and controlgear – Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV - Edition 3.0
Show full item record
contributor author | IEC - International Electrotechnical Commission | |
date accessioned | 2020-09-15T22:28:09Z | |
date available | 2020-09-15T22:28:09Z | |
date copyright | 2019.05.01 | |
date issued | 2019 | |
identifier other | POOYHGAAAAAAAAAA.pdf | |
identifier other | POOYHGAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std;jsein/handle/yse/288966 | |
description abstract | Scope: This part of IEC 62271 applies to three-pole-operated fused circuit-switchers designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. They can be designed either as stand-alone devices, or be embedded in a switchgear and controlgear assembly. They are intended to be used for circuits or applications requiring only a normal mechanical and electrical endurance capability. Such applications cover protection of HV/LV transformers for instance, but exclude distribution lines or cables, as well as motor circuits and capacitor bank circuits. Short-circuit conditions with low currents, up to the fused circuit-switcher rated take-over current, are dealt with by supplementary devices (strikers, relays, etc.), properly arranged, tripping the circuit-switcher. Current-limiting fuses are incorporated in order to ensure that the short-circuit breaking capacity of the device is above that of the circuit-switcher alone. NOTE 1 In this document, the term "fuse" is used to designate either the fuse or the fuse-link where the general meaning of the text does not result in ambiguity. NOTE 2 Other circuit-switchers exist; see reference [4]. Devices that require a dependent manual operation are not covered by this document. | |
language | English | |
title | English -- High-voltage switchgear and controlgear – Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV - Edition 3.0 | en |
title | IEC 62271-107 (REDLINE + STANDARD) | num |
type | standard | |
page | 176 | |
status | Active | |
tree | IEC - International Electrotechnical Commission:;2019 | |
contenttype | fulltext |