Archive

English -- High-voltage switchgear and controlgear – Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV - Edition 3.0

IEC 62271-107 (REDLINE + STANDARD)

Organization:
IEC - International Electrotechnical Commission
Year: 2019

Abstract: Scope: This part of IEC 62271 applies to three-pole-operated fused circuit-switchers designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. They can be designed either as stand-alone devices, or be embedded in a switchgear and controlgear assembly. They are intended to be used for circuits or applications requiring only a normal mechanical and electrical endurance capability. Such applications cover protection of HV/LV transformers for instance, but exclude distribution lines or cables, as well as motor circuits and capacitor bank circuits. Short-circuit conditions with low currents, up to the fused circuit-switcher rated take-over current, are dealt with by supplementary devices (strikers, relays, etc.), properly arranged, tripping the circuit-switcher. Current-limiting fuses are incorporated in order to ensure that the short-circuit breaking capacity of the device is above that of the circuit-switcher alone. NOTE 1 In this document, the term "fuse" is used to designate either the fuse or the fuse-link where the general meaning of the text does not result in ambiguity. NOTE 2 Other circuit-switchers exist; see reference [4]. Devices that require a dependent manual operation are not covered by this document.
URI: http://yse.yabesh.ir/std;jsein/handle/yse/288966
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (2.534Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    English -- High-voltage switchgear and controlgear – Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV - Edition 3.0

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2020-09-15T22:28:09Z
date available2020-09-15T22:28:09Z
date copyright2019.05.01
date issued2019
identifier otherPOOYHGAAAAAAAAAA.pdf
identifier otherPOOYHGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsein/handle/yse/288966
description abstractScope: This part of IEC 62271 applies to three-pole-operated fused circuit-switchers designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. They can be designed either as stand-alone devices, or be embedded in a switchgear and controlgear assembly. They are intended to be used for circuits or applications requiring only a normal mechanical and electrical endurance capability. Such applications cover protection of HV/LV transformers for instance, but exclude distribution lines or cables, as well as motor circuits and capacitor bank circuits. Short-circuit conditions with low currents, up to the fused circuit-switcher rated take-over current, are dealt with by supplementary devices (strikers, relays, etc.), properly arranged, tripping the circuit-switcher. Current-limiting fuses are incorporated in order to ensure that the short-circuit breaking capacity of the device is above that of the circuit-switcher alone. NOTE 1 In this document, the term "fuse" is used to designate either the fuse or the fuse-link where the general meaning of the text does not result in ambiguity. NOTE 2 Other circuit-switchers exist; see reference [4]. Devices that require a dependent manual operation are not covered by this document.
languageEnglish
titleEnglish -- High-voltage switchgear and controlgear – Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV - Edition 3.0en
titleIEC 62271-107 (REDLINE + STANDARD)num
typestandard
page176
statusActive
treeIEC - International Electrotechnical Commission:;2019
contenttypefulltext