IEEE Guide for Properties of Stripes and Ridges for Identification of Underground Power Cable Jackets and Ducts - Redline
IEEE Std 1235-2023 (Revision of IEEE Std 1235-2000) - Redline
Year: 2023
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Abstract: Recommendations for colored stripes and raised ridges as identification markings on non-conducting and semiconducting underground power cable jackets are provided in this guide. Typically, power cables are identified by red stripes; however, other colors may be permitted. The guide also applies to the duct containing jacketed or unjacketed underground power cables. The colored stripe recommendations include the number of stripes, color, width, thickness, color retention characteristics, physical properties, storage criteria, and test methods. The raised ridge recommendations include physical properties, width, height, and circumferential spacing. It is the intent of this guide to provide a minimum level of physical, chemical, and color stability of colored stripes used to identify underground power cable jackets and ducts.
Subject: stripes
-
Statistics
IEEE Guide for Properties of Stripes and Ridges for Identification of Underground Power Cable Jackets and Ducts - Redline
Show full item record
contributor author | IEEE - The Institute of Electrical and Electronics Engineers, Inc. | |
date accessioned | 2024-12-17T08:09:27Z | |
date available | 2024-12-17T08:09:27Z | |
date copyright | 31 March 2023 | |
date issued | 2023 | |
identifier other | 10184941.pdf | |
identifier uri | http://yse.yabesh.ir/std;jsein/handle/yse/336365 | |
description abstract | Recommendations for colored stripes and raised ridges as identification markings on non-conducting and semiconducting underground power cable jackets are provided in this guide. Typically, power cables are identified by red stripes; however, other colors may be permitted. The guide also applies to the duct containing jacketed or unjacketed underground power cables. The colored stripe recommendations include the number of stripes, color, width, thickness, color retention characteristics, physical properties, storage criteria, and test methods. The raised ridge recommendations include physical properties, width, height, and circumferential spacing. It is the intent of this guide to provide a minimum level of physical, chemical, and color stability of colored stripes used to identify underground power cable jackets and ducts. | |
language | English | |
publisher | IEEE - The Institute of Electrical and Electronics Engineers, Inc. | |
title | IEEE Guide for Properties of Stripes and Ridges for Identification of Underground Power Cable Jackets and Ducts - Redline | en |
title | IEEE Std 1235-2023 (Revision of IEEE Std 1235-2000) - Redline | num |
type | standard | |
page | 30 | |
status | Active | |
tree | IEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2023 | |
contenttype | fulltext | |
subject keywords | stripes | |
subject keywords | raised ridges | |
subject keywords | identification markings | |
subject keywords | IEEE 1235 | |
subject keywords | power cables |