TIA TIA-1194

Telecommunications User Premises Equipment Surge Resistibility of Smart Grid Equipment Connected to either DC or 120/240 V Single Phase AC and Metallic Communication Lines

Organization:
TIA - Telecommunications Industry Association
Year: 2011

Abstract: This Standard applies to premises equipment that is connected to one or more metallic conductive communication line(s) and either a DC power source, or a 120/240 V single phase AC power service with the neutral grounded at the service entrance. It specifies the test procedures and resistibility requirements under which the communications ports of the equipment shall continue to demonstrate basic functionality when subjected to overvoltages and overcurrents on either the power lines or the communications line(s). Overvoltages or overcurrents covered by this Standard include surges due to lightning on or near the power lines or telecommunications line(s). This Standard covers the case where two or more services connected to the equipment have ground connections that may be separated by significant impedance.
PURPOSE
Most standards for the resistibility of equipment to electrical surges assume that a zero (or very low) impedance exists among all the grounds in the equipment, or among the connections to separate earth grounds. For equipment installed in the smart grid (or indeed, anywhere), the impedance of the ground connections may be significant. The purpose of this standard is to provide tests and performance criteria for the resistibility to lightning strikes of equipment connected to two or more services having at least one ground connection separated from the others by a significant impedance.
Examples of equipment with services having separate grounds include a smart grid power meter that is connected to the AC power at one side of a building and a communications service at the opposite side or a roof-mounted photovoltaic system with a communications link to the smart grid (see Figure 1).
URI: http://yse.yabesh.ir/std;jsein=autho17/handle/yse/156110
Collections :
  • TIA - Telecommunications Industry Association
  • Download PDF : (707.0Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    TIA TIA-1194

Show full item record

contributor authorTIA - Telecommunications Industry Association
date accessioned2017-09-04T17:33:09Z
date available2017-09-04T17:33:09Z
date copyright40865
date issued2011
identifier otherDCBWTEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsein=autho17/handle/yse/156110
description abstractThis Standard applies to premises equipment that is connected to one or more metallic conductive communication line(s) and either a DC power source, or a 120/240 V single phase AC power service with the neutral grounded at the service entrance. It specifies the test procedures and resistibility requirements under which the communications ports of the equipment shall continue to demonstrate basic functionality when subjected to overvoltages and overcurrents on either the power lines or the communications line(s). Overvoltages or overcurrents covered by this Standard include surges due to lightning on or near the power lines or telecommunications line(s). This Standard covers the case where two or more services connected to the equipment have ground connections that may be separated by significant impedance.
PURPOSE
Most standards for the resistibility of equipment to electrical surges assume that a zero (or very low) impedance exists among all the grounds in the equipment, or among the connections to separate earth grounds. For equipment installed in the smart grid (or indeed, anywhere), the impedance of the ground connections may be significant. The purpose of this standard is to provide tests and performance criteria for the resistibility to lightning strikes of equipment connected to two or more services having at least one ground connection separated from the others by a significant impedance.
Examples of equipment with services having separate grounds include a smart grid power meter that is connected to the AC power at one side of a building and a communications service at the opposite side or a roof-mounted photovoltaic system with a communications link to the smart grid (see Figure 1).
languageEnglish
titleTIA TIA-1194num
titleTelecommunications User Premises Equipment Surge Resistibility of Smart Grid Equipment Connected to either DC or 120/240 V Single Phase AC and Metallic Communication Linesen
typestandard
page26
statusActive
treeTIA - Telecommunications Industry Association:;2011
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian