ACI SP-315

Punching shear of structural concrete slabs

Organization:
ACI - American Concrete Institute
Year: 2017

Abstract: The Strip Model describes a load path for the transfer of vertical shear between a slab and column. The model is easily adapted to design but its application to the analysis of specimens tested under combined shear and moment is less clear. This paper provides a brief description of the Strip Model, updates the model to include size effect, and shows how it can be applied to interior and edge column-slab connections transferring combinations of shear and moment.
URI: http://yse.yabesh.ir/std;jsein=autho4/handle/yse/265594
Collections :
  • ACI - American Concrete Institute
  • Download PDF : (80.64Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ACI SP-315

Show full item record

contributor authorACI - American Concrete Institute
date accessioned2018-10-06T07:12:17Z
date available2018-10-06T07:12:17Z
date copyright2017.01.01
date issued2017
identifier otherRUQBBGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsein=autho4/handle/yse/265594
description abstractThe Strip Model describes a load path for the transfer of vertical shear between a slab and column. The model is easily adapted to design but its application to the analysis of specimens tested under combined shear and moment is less clear. This paper provides a brief description of the Strip Model, updates the model to include size effect, and shows how it can be applied to interior and edge column-slab connections transferring combinations of shear and moment.
languageEnglish
titleACI SP-315num
titlePunching shear of structural concrete slabsen
typestandard
page396
statusActive
treeACI - American Concrete Institute:;2017
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian