• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • ACI - American Concrete Institute
  • View Item
  •   YSE
  • Industrial Standards
  • ACI - American Concrete Institute
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

ACI 332

Residential Code Requirements for Structural Concrete (ACI 332-10) and Commentary

Organization:
ACI - American Concrete Institute
Year: 2014

Abstract: This code, when legally adopted as part of a general building code, provides minimum requirements for design and construction of residential concrete elements. In areas without a legally adopted building code and lack of a project specification, this code defines minimum acceptable standards of design and construction practice.
This code supplements the general building code and governs matters pertaining to design and construction of cast-in-place concrete construction for one- and two-family dwellings and multiple single-family dwellings (townhouses), and their accessory structures, except wherever this code conflicts with requirements in the legally adopted general building code.
Where this code conflicts with requirements contained in other standards referenced in this code, this code shall govern.
This code is limited to design and construction of concrete footings, including thickened slab footings, wall footings, and isolated footings; concrete basement or foundation walls constructed with removable forms or with flat insulating concrete forms; and concrete slabs-on-ground.
Where the scope of this code and the scope of ACI 318 coincide, design in accordance with ACI 318 shall be permitted for all buildings and structures, and all parts thereof, within the scope of this code.
This code does not govern design and construction of insulating concrete form walls with a waffle or screen configuration; precast wall elements; above-grade concrete walls; deep foundation systems, such as piles, drilled piers, or caissons; and elevated concrete slabs.
This code does not govern the design and application of systems for surface drainage, waterproofing, dampproofing, or the ventilation of radon gases.
When a building or structure contains elements that exceed the limits of this code or otherwise do not conform to this code, these elements shall be designed in accordance with ACI 318.
Where permitted by the statutes of the jurisdiction where the project is to be constructed, construction documents for residences designed by the provisions of this code need not be prepared by a licensed design professional. Where required by the statutes of the jurisdiction where the project is to be constructed, a licensed design professional shall prepare the construction documents for residences.
This code is intended to state only minimum requirements necessary to provide for public health and safety for the design of residences that fall within the scope of the IRC-2012. The owner or the licensed design professional may require the quality of materials and construction to be higher than the minimum requirements stated in the code.
All references to minimum and maximum dimensions or values in the code refer to those dimensions or values as specified.
This code is not intended to define contractual responsibilities between all the parties involved in a project, nor is it intended to settle disputes regarding contractual responsibilities.
The commentary text, tables, figures, or illustrations shall not be used to interpret the code in a way that conflicts with the plain meaning of the code text, or to create ambiguity within the code that would not otherwise exist.
The English version in U.S. customary units is the official version of the code. In case of conflict between the official version and versions with SI units or in different languages, the official version governs.
URI: http://yse.yabesh.ir/std;jsein=autho4/handle/yse/91431
Collections :
  • ACI - American Concrete Institute
  • Download PDF : (878.1Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ACI 332

Show full item record

contributor authorACI - American Concrete Institute
date accessioned2017-09-04T16:28:17Z
date available2017-09-04T16:28:17Z
date copyright2014.02.01
date issued2014
identifier otherUFIPHFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsein=autho4/handle/yse/91431
description abstractThis code, when legally adopted as part of a general building code, provides minimum requirements for design and construction of residential concrete elements. In areas without a legally adopted building code and lack of a project specification, this code defines minimum acceptable standards of design and construction practice.
This code supplements the general building code and governs matters pertaining to design and construction of cast-in-place concrete construction for one- and two-family dwellings and multiple single-family dwellings (townhouses), and their accessory structures, except wherever this code conflicts with requirements in the legally adopted general building code.
Where this code conflicts with requirements contained in other standards referenced in this code, this code shall govern.
This code is limited to design and construction of concrete footings, including thickened slab footings, wall footings, and isolated footings; concrete basement or foundation walls constructed with removable forms or with flat insulating concrete forms; and concrete slabs-on-ground.
Where the scope of this code and the scope of ACI 318 coincide, design in accordance with ACI 318 shall be permitted for all buildings and structures, and all parts thereof, within the scope of this code.
This code does not govern design and construction of insulating concrete form walls with a waffle or screen configuration; precast wall elements; above-grade concrete walls; deep foundation systems, such as piles, drilled piers, or caissons; and elevated concrete slabs.
This code does not govern the design and application of systems for surface drainage, waterproofing, dampproofing, or the ventilation of radon gases.
When a building or structure contains elements that exceed the limits of this code or otherwise do not conform to this code, these elements shall be designed in accordance with ACI 318.
Where permitted by the statutes of the jurisdiction where the project is to be constructed, construction documents for residences designed by the provisions of this code need not be prepared by a licensed design professional. Where required by the statutes of the jurisdiction where the project is to be constructed, a licensed design professional shall prepare the construction documents for residences.
This code is intended to state only minimum requirements necessary to provide for public health and safety for the design of residences that fall within the scope of the IRC-2012. The owner or the licensed design professional may require the quality of materials and construction to be higher than the minimum requirements stated in the code.
All references to minimum and maximum dimensions or values in the code refer to those dimensions or values as specified.
This code is not intended to define contractual responsibilities between all the parties involved in a project, nor is it intended to settle disputes regarding contractual responsibilities.
The commentary text, tables, figures, or illustrations shall not be used to interpret the code in a way that conflicts with the plain meaning of the code text, or to create ambiguity within the code that would not otherwise exist.
The English version in U.S. customary units is the official version of the code. In case of conflict between the official version and versions with SI units or in different languages, the official version governs.
languageEnglish
titleACI 332num
titleResidential Code Requirements for Structural Concrete (ACI 332-10) and Commentaryen
typestandard
page58
statusActive
treeACI - American Concrete Institute:;2014
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian